Skip to main content

BAPI BA/AQX-G : Dual Channel CO2 Room Sensor for Continuously Occupied Areas, Field Selectable Voltage Output - 0 to 5V Default, 0 to 10,000 ppm Range, 5-Year Warranty

BAPI

MSRP: $455.00
$197.00
(You save $258.00 )
(No reviews yet) Write a Review
SKU:
BA/AQX-G
Condition:
New
Availability:
Ships 2 Weeks
Adding to cart… The item has been added

BAPI BA/AQX-G : Dual Channel CO2 Room Sensor for Continuously Occupied Areas, Field Selectable Voltage Output - 0 to 5V Default, 0 to 10,000 ppm Range, 5-Year Warranty

Ensure optimal indoor air quality and energy efficiency in continuously occupied areas with the BAPI BA/AQX-G CO2 sensor. This dual-channel sensor offers a wide detection range of up to 10,000 ppm, making it ideal for larger spaces or those with fluctuating occupancy levels.

Key features include:

  • Dual-channel technology for reliable readings even in environments with temperature or pressure variations.
  • Field-selectable voltage output (0-5V default) for seamless integration with your existing HVAC system.
  • Automatic temperature and pressure compensation for accurate readings regardless of external conditions.
  • Multiple mounting options for flexible placement to ensure optimal coverage.
  • 5-year warranty for peace of mind and long-term performance.

Benefits of using the BAPI BA/AQX-G CO2 sensor:

  • Enhanced indoor air quality by maintaining optimal ventilation based on real-time CO2 levels.
  • Reduced energy costs by minimizing unnecessary ventilation when CO2 levels are low.
  • Improved occupant comfort and well-being by reducing CO2 buildup, which can lead to fatigue, headaches, and poor concentration.
  • Simple installation and maintenance for hassle-free operation.

Specifications

Power: 12 to 24 VDC, 240 mA • 18 to 24 VAC, 12 VA Peak
CO2 Sensing Element: Dual Channel Non-Dispersive Infrared (NDIR)
Field Selectable Voltage Output: 0 to 5 or 0 to 10 VDC
Termination:  3 Terminals, 16 to 22 AWG
Operating Environment: 32 to 122°F (0 to 50°C)
0 to 95%RH non-condensing
Enclosure Material:
ABS Plastic, Material Rated UL94 V-O
CO2 Detection Range: 0 to 10,000
Start-Up Time:
<2 Minutes
Response Time: <2 Minutes for 90% step change typical (after start-up)
Mounting: Standard 2”x4” junction box, European junction box or drywall mount (screws provided)
CO2 Accuracy: 400 to 1,000 ppm: ±75 ppm
>1,000 ppm: ±10% of reading
CO2 Drift Stability: <5% of full scale over life of product.
Agency: RoHS, CE, Title 24 Requirements

 

Datasheets

pdf logo BAPI CO2 Room Sensor, BAPI-Stat “Quantum” Enclosure, Datasheet for Submittal
pdf logo BAPI-Stat “Quantum” CO2 Room Sensor Instructions
pdf logo Effects of Temperature and Barometric Pressure on CO2 Measurement
pdf logo Calibration Methods for Single and Dual Beam CO2 Sensors

 

Sensor Type:
Wall
Humidity Element:
None
CO2 Element:
Yes
Temperature Element:
None
Display:
No Display
VOC:
No