null Skip to main content

Dwyer RHPX-3SDA0-00-LCD : Duct Mount Humidity and Temperature Transmitter, 3% RH Accuracy, Selectable 4-20 mA / 0-5 / 0-10 VDC Humidity Output, Active Analog Temp Output, Two-Line LCD Display, IP66 / NEMA 4X, 5-Year Warranty

Dwyer

MSRP: $299.05
Your Price:  $242.00
(You save $57.05 )
(No reviews yet) Write a Review
SKU:
RHPX-3SDA0-00-LCD
Condition:
New
Availability:
1 In Stock | Lead Time: 5 weeks
Adding to cart… The item has been added
Mounting
Duct Mount
RH Accuracy
±3% RH
RH Output
4-20 mA / 0-5 V / 0-10 V
Active Temp Output
Selectable Analog
Enclosure
Small, IP66 / NEMA 4X
Display
Two-Line LCD
Warranty
5 Years

The Dwyer RHPX-3SDA0-00-LCD is a duct mount humidity and temperature transmitter from the Dwyer Series RHPX, built around a capacitive polymer humidity sensor rated to ±3% RH across 10% to 90% RH at 25°C (77°F). Humidity output is field selectable between 4-20 mA, 0-5 V dc and 0-10 V dc, alongside an active analog temperature output on the same selectable range. The plenum plastic probe carries a hydrophobic filter for duct air streams. The housing is UL 94 V-0 rated to IP66 / NEMA Type 4X, and on-board DIP switches select imperial or metric units, voltage or current output, and whether the humidity channel reports relative humidity, dew point, enthalpy or absolute humidity.

Best For
  • Duct-mounted humidity and temperature measurement, installed per the duct mounting procedure in AQ-RHPX-A
  • Air economizer sequences using the selectable enthalpy or dew point humidity output
  • Dwyer publishes these Series RHPX applications: air economizers, outdoor humidity and temperature reference, pool room humidity monitoring, building energy management systems, commercial HVAC systems, clean rooms, museums and data centers
5 Year Limited Warranty

Key Features

Active Analog Temperature Output

Temperature is transmitted on a field-selectable 4-20 mA, 0-5 V dc or 0-10 V dc output from a solid state band gap element accurate to ±0.9°F @ 77°F (±0.5°C @ 25°C).

±3% RH Capacitive Polymer Sensor

Humidity sensor accuracy is ±3% at 10% to 90% RH and 25°C (77°F), across a full 0% to 100% measurement range, with 0.1% RH resolution.

Four Selectable Humidity Metrics

DIP switches 4 and 5 set the humidity channel to relative humidity, enthalpy, dew point or absolute humidity. Absolute humidity spans 0 to 50 g/m3, dew point -75°C to 60°C, and enthalpy -40 to 411 kJ/kg.

Field-Selectable Output and Units

DIP switch 1 selects metric or imperial units, switch 2 selects 0-10 V or 0-5 V, and switch 3 selects voltage or 4-20 mA output. Default is imperial units, 4-20 mA, %RH. On-board trimmers allow ±3.5% RH and ±5°F field offset.

Two-Line Alphanumeric Display

The LCD shows two lines of eight alphanumeric characters, allowing temperature and humidity to be read at the device. Operating range narrows to -20°C to 60°C (-4°F to 140°F) with the display fitted.

Compliance

The Series RHPX carries BTL and CE compliance. Dwyer qualifies its UL 60335-2-40 listing as meeting UL 60335-2 clause 30.103DV.1 through UL 2043 compliance. UL 2043 plenum compliance is limited to the specific model groups named in DS-RHPX Rev.1, which do not include this model.

Technical Specifications

Model / SKURHPX-3SDA0-00-LCD
Sensor ConfigurationD — Duct mount with plenum plastic probe and hydrophobic filter
Enclosure SizeS — Small enclosure
Humidity Measurement Range0% to 100% humidity
Humidity Sensor Accuracy±3%, at 10% to 90% RH and 25°C (77°F)
Humidity SensorCapacitive polymer
Temperature Measurement Range-40°C to 60°C (-40°F to 140°F)
Humidity Analog Output4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable
Active Temperature Analog Output4-20 mA or 0-5 V dc, 0-10 V dc at 5 mA max, field selectable
Active Temperature Accuracy (Solid State Band Gap)±0.9°F @ 77°F (±0.5°C @ 25°C)
Passive Temperature SensorNone on this model (order code 0)
Power Requirements4-20 mA: 10 to 35 Vdc. Voltage output: 15 to 35 Vdc or 15 to 29 Vac
Wiring ConnectionRemovable terminal block, 18 AWG maximum
ResolutionRelative humidity 0.1%; temperature 0.1°F/°C; absolute humidity 0.1 g/m3
Additional CalculationsAbsolute humidity 0 to 50 g/m3 or 0 to 3000 lb/mmcf; dew point -75°C to 60°C (-102°F to 140°F); enthalpy -40 to 411 kJ/kg or -17 to 177 Btu/lb
Operating Temperature Range-20°C to 60°C (-4°F to 140°F), with LCD
Storage Temperature-30°C to 70°C (-22°F to 158°F), with LCD
DisplayTwo lines of alphanumeric characters, eight characters per line
Electrical Entry1/2 in NPS thread, cable gland included
Enclosure MaterialUL 94 V-0
Enclosure RatingIP66, NEMA Type 4X
Duct Installation1 in diameter duct hole; four #8 x 1/2 in pan head sheet metal screws
Product Weight198.4 g (0.44 lb), duct configuration
ComplianceBTL, CE. Dwyer qualifies UL 60335-2-40 as meeting UL 60335-2 clause 30.103DV.1 through UL 2043 compliance, which this model does not carry.
Warranty5 year limited warranty
The UL 2043 compliance footnote in DS-RHPX Rev.1 scopes plenum compliance to models without an LCD display. No UL 2043 rating is claimed for this LCD-equipped model.

Documentation

Related Products

Frequently Asked Questions

What do the characters in RHPX-3SDA0-00-LCD mean?

Reading the Dwyer order code left to right: RHPX is the series, 3 is 3% RH accuracy, S is the small enclosure, D is Duct mount with plenum plastic probe and hydrophobic filter, A is the selectable analog output, 0 is no passive temperature sensor, and 00 is the cable length option.

Does this model have an LCD display?

Yes. It is fitted with a two-line alphanumeric display, eight characters per line. Note that the operating range narrows to -20°C to 60°C (-4°F to 140°F) with the display fitted.

Can it output dew point or enthalpy instead of relative humidity?

Yes. DIP switches 4 and 5 set the humidity channel output to relative humidity, enthalpy, dew point or absolute humidity. The default setting is %RH.

What supply voltage does it need?

It depends on the output mode selected. In 4-20 mA mode the transmitter needs 10 to 35 V dc. In voltage output mode it needs 15 to 35 V dc or 15 to 29 V ac. The 4-20 mA models are not designed for AC voltage operation.

Is this model plenum rated?

No. The UL 2043 compliance footnote in DS-RHPX Rev.1 does not cover this model, so no plenum rating is claimed for it.

Is the RHPX field serviceable?

No. Dwyer states the Series RHPX requires no routine maintenance, is not field serviceable, and cannot be repaired. Field repair should not be attempted and may void the warranty.

Specifications on this page are drawn from Dwyer DS-RHPX Rev.1 (Printed in U.S.A. 3/24) and the Series RHPX Analog Transmitter User Guide, Bulletin AQ-RHPX-A (FR# 444702-00 Rev. 1) (3/24). Where the catalog page and the datasheet differ, DS-RHPX Rev.1 governs. Verified 2026-08-29. ZOT Supply is an authorized DwyerOmega distributor.

5 Year Limited Warranty. The Dwyer Series RHPX carries a five year limited warranty as published on the Dwyer Series RHPX catalog page. Warranty and return handling follow the Terms and Conditions of Sale published by Dwyer Instruments, LLC. Contact customer service for a Return Materials Authorization (RMA) number before shipping any product back for repair, and include a brief description of the problem plus any application notes.

The Series RHPX requires no routine maintenance, is not field serviceable, and cannot be repaired. Field repair should not be attempted and may void the warranty.

ZOT Supply is an authorized DwyerOmega distributor. Warranty support is handled through ZOT Supply at sales@zotsupply.com or 855-825-2811.

Sensor Type:
Duct
Humidity Element:
3%
Series:
RHPX
Humidity Output:
4–20 mA (loop output)
Humidity Output:
0–5V or 0–10V (jumper-selectable)
Supported Protocols:
None (analog)
Temperature Element:
Solid State Band Gap
Display:
LCD Display
Enclosure:
NEMA 4X Enclosure
CO2 Element:
None
Material:
Plastic