PL-PROPACK-VAV: VAV ProPack Kit. Includes PL-VC2000-PI Controller, PL-T1000-WGL Wall Sensor, PL-DT-T6 Duct Temperature Sensor. Includes wiring diagram and quick installation instructions.
The Prolon PL-PROPACK-VAV is a grab-and-go VAV ProPack built for pressure independent zone applications. This kit streamlines typical VAV installs by bundling the core controller, zone wall sensor, duct temperature sensor, and the wiring and setup guidance you need to get up and running quickly.
Common Applications
- Pressure independent VAV zone control (single-zone VAV boxes)
- HVAC contractor “standard kit” installs to reduce missing parts and callbacks
- Zone temperature control using a wall sensor with optional network integration
- Installs requiring a duct temperature sensor at the inlet (supply air from RTU/AHU)
Specifications:
- Kit Includes
- PL-VC2000-PI VAV Controller
- PL-T1000-WGL Wall Sensor (T1000 series wall module)
- PL-DT-T6 Duct Temperature Sensor
- Quick installation instructions and wiring diagram
- Power
- 24 VAC required (transformer not included)
- Allow 5 VA per PL-VC2000-PI controller when sizing a transformer
- Wiring Guidance
- 24 VAC supply wiring: #18/2 AWG stranded
- Wall sensor data wiring: #22/2 AWG stranded, shielded, low capacitance (twisted pair recommended)
- Duct temperature sensor connects to the controller analog input terminals 13 and 14
- Network and Connectivity (Optional)
- Controller can be networked to other Prolon devices via RS485 terminals (NET A / NET B) in a daisy chain
- Internet connectivity requires a PL-NC2000 Network Controller (not included)
- Wireless wall sensor capability supported using PL-TREE-COM adapters (not included). Both devices still require 24 VAC power.
- Smartphone app and Focus software configuration supported using the PL-485-BT Prolon Connection Tool (optional, not included)
- Operation Notes (From Included Guide)
- Pressure independent airflow control uses high and low pressure pickup tubing from the airflow measuring station
- Occupied mode setpoints come from the wall sensor. Damper behavior responds to space demand and duct temperature relationship
- Default airflow setpoints shown in the guide (pressure independent): Min Vent SP 90 CFM. Max Vent SP 225 CFM
- What’s Not Included
- 24 VAC transformer
- Field wiring (24 VAC and data cable)
- PL-485-BT Connection Tool (optional)
Construction
| Component | Details |
|---|---|
| Controller | PL-VC2000-PI VAV Controller with onboard actuator setup support and optional network integration. |
| Wall Sensor | PL-T1000-WGL wall module for zone temperature input and controller setup/navigation. |
| Duct Temperature Sensor | PL-DT-T6 sensor intended for inlet (supply air) temperature monitoring from the RTU/AHU. |
| Documentation | Quick installation instructions and wiring diagram included with the kit. |
Datasheets
| Document | Link | |
|---|---|---|
| VAV ProPack Quick Installation Instructions and Wiring Diagram | ? | View PDF |
| Prolon ProPacks Overview (Available ProPacks and ProPack Advantage) | ? | View PDF |
- Controller Type:
- Rooftop
- Digital Outputs:
- 5
- Analog Outputs:
- 3
- Inputs:
- 9
- Communication:
- Modbus RTU (RS485)