Skip to main content

Senva AQ2D-BC2AAAD : Duct Mount TotalSense RH/CO2 Sensor, BACnet/Modbus Output, CO2, 2% RH Accurracy, OLED Display, Buy American Act Compliant, 7-Year Limited Warranty

Senva

MSRP: $765.00
$302.00
(You save $463.00 )
(No reviews yet) Write a Review
SKU:
AQ2D-BC2AAAD
Condition:
New
Availability:
Ships in 2 Days
Adding to cart… The item has been added

Senva AQ2D-BC2AAAD : Duct Mount TotalSense Sensor, BACnet/Modbus Output, CO2, 2% RH Accurracy, OLED Display, Buy American Act Compliant, 7-Year Limited Warranty

The Senva AQ2D-BC2AAAD is a duct-mounted sensor designed to monitor carbon dioxide (CO2) and relative humidity (RH) within ventilation systems. Equipped with BACnet/Modbus communication protocols, it seamlessly integrates into building automation systems.

Key features include:

  • High accuracy: Measures CO2 with ±(30ppm + 3% of reading) and RH with ±2% accuracy.
  • Wide range: Detects CO2 levels from 0-10,000ppm and RH from 0-80%.
  • Easy monitoring: Features a clear OLED display for real-time data visualization.
  • Reliable communication: Supports BACnet MS/TP or Modbus RTU protocols for seamless integration.
  • Long-lasting performance: Backed by a 7-year limited warranty.

Additional specifications:

  • Power supply: 24-30VDC/24VAC
  • Enclosure: Durable ABS plastic
  • Compliance: CE, RoHS

Ideal for applications requiring precise air quality monitoring in buildings, such as schools, offices, and healthcare facilities.

Specifications

Power Supply 24-30VDC/24VAC(1), 4.3W nominal, 5W max.
Interface 1.5” Organic LED Display, 128x128, color
Protocol Output BACnet MS/TP or Modbus RTU
Relay Type Solid-state output, 1A @ 30VAC/DC, N.O.
Relay Polarity NO/NC (selectable)
CO2
 
Type Non-dispersive Infrared (NDIR)
Accuracy ±(30ppm + 3% of reading) (400-2,000ppm), -10-50ºC, 0-85%RH
±(50ppm+ 5% of reading) (2,000-5,000ppm), -10-50ºC, 0-85%RH
>5,000ppm consult factory
Resolution 1 ppm
Range 0-2,000 PPM (Default) (Programmable up to 10,000ppm)
Response time
90 seconds to 90% reading
Response Rate 1s
Temp and Pressure Compensation
Yes, barometric pressure readable over comms
Relative Humidity 2% models, +/-2% over 0 to 80%RH range
Enclosure ABS Plastic / 4.0"h x 4.4"w x x2.1"d (+6.8" probe)
Compliance CE, RoHS

 

Datasheets

pdf logo Senva AQ2D TotalSense RH/CO2 TotalSense Duct
pdf logo Senva AQ2D RH/CO2 Duct Installation
pdf logo Senva AQ2D Display Navigation Guide TotalSense Series
pdf logo Senva Made In USA Certificate 2023
Sensor Type:
Duct
Output Signal:
BACnet/Modbus Only
CO2 Element:
Yes
Humidity Element:
2%
VOC Element:
None
Temperature Element:
None
Display:
OLED Display
Supported Protocols:
BACnet/Modbus