Skip to main content

Senva AQ2D-BD2AAAD : Duct Mount TotalSense RH/CO2 Sensor, BACnet/Modbus Output, Dual Channel CO2, 2% RH Accurracy, OLED Display, Buy American Act Compliant, 7-Year Limited Warranty

Senva

MSRP: $810.00
$320.00
(You save $490.00 )
(No reviews yet) Write a Review
SKU:
AQ2D-BD2AAAD
Condition:
New
Availability:
Ships in 2 Days
Adding to cart… The item has been added

Senva AQ2D-BD2AAAD : Duct Mount TotalSense Sensor, BACnet/Modbus Output, Dual Channel CO2, 2% RH Accurracy, OLED Display, Buy American Act Compliant, 7-Year Limited Warranty

The Senva AQ2D-BD2AAAD sensor offers comprehensive monitoring of air quality within duct systems. It measures both carbon dioxide (CO2) and relative humidity (RH) with high accuracy.

Key features include:

  • Dual channel CO2 sensing: Ensures precise CO2 detection.
  • 2% RH accuracy: Provides reliable humidity readings.
  • BACnet/Modbus output: Enables seamless integration with building management systems.
  • OLED display: Offers clear on-site data visualization.
  • Long-lasting performance: Backed by a 7-year limited warranty.

Additional specifications:

  • Wide operating voltage range (24-30VDC/24VAC)
  • Compact and durable ABS plastic enclosure
  • Selectable relay type (NO/NC) for flexible control
  • NDIR CO2 sensor technology for accurate readings

This American-made sensor is ideal for maintaining optimal air quality in various applications, including:

  • Commercial buildings
  • Educational facilities
  • Healthcare settings

Note: Consult the manufacturer for CO2 readings exceeding 5,000ppm.

Specifications

Power Supply 24-30VDC/24VAC(1), 4.3W nominal, 5W max.
Interface 1.5” Organic LED Display, 128x128, color
Protocol Output BACnet MS/TP or Modbus RTU
Relay Type Solid-state output, 1A @ 30VAC/DC, N.O.
Relay Polarity NO/NC (selectable)
CO2
 
Type Non-dispersive Infrared (NDIR)
Accuracy ±(30ppm + 3% of reading) (400-2,000ppm), -10-50ºC, 0-85%RH
±(50ppm+ 5% of reading) (2,000-5,000ppm), -10-50ºC, 0-85%RH
>5,000ppm consult factory
Resolution 1 ppm
Range 0-2,000 PPM (Default) (Programmable up to 10,000ppm)
Response time
90 seconds to 90% reading
Response Rate 1s
Temp and Pressure Compensation
Yes, barometric pressure readable over comms
Relative Humidity 2% models, +/-2% over 0 to 80%RH range
Enclosure ABS Plastic / 4.0"h x 4.4"w x x2.1"d (+6.8" probe)
Compliance CE, RoHS

 

Datasheets

pdf logo Senva AQ2D TotalSense RH/CO2 TotalSense Duct
pdf logo Senva AQ2D RH/CO2 Duct Installation
pdf logo Senva AQ2D Display Navigation Guide TotalSense Series
pdf logo Senva Made In USA Certificate 2023
Sensor Type:
Duct
Output Signal:
BACnet/Modbus Only
CO2 Element:
Yes
Humidity Element:
2%
VOC Element:
None
Temperature Element:
None
Display:
OLED Display
Supported Protocols:
BACnet/Modbus