null Skip to main content

Senva CT1D-B3D : Duct CO2/Temperature Combo Sensor, Temperature Transmitter, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, LCD Display, 7-Year Limited Warranty

Senva

MSRP: $601.66
Your Price:  $259.55
(You save $342.11 )
(No reviews yet) Write a Review
SKU:
CT1D-B3D
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
CO2 Range0-2000 / 0-5000 / 0-10000 ppm (selectable)
Temp ElementTransmitter (Active)
DisplayLCD + Menu Buttons
Outputs4-20mA / 0-5V / 0-10V
Setpoint RelaySolid-State, Adjustable
OriginMade in USA

The Senva CT1D-B3D is a duct-mount NDIR carbon dioxide (CO2) and temperature transmitter. CO2 is reported over selectable 4-20mA, 0-5V, or 0-10V outputs, and an onboard active temperature transmitter provides a second analog output with a field-selectable range. An integrated solid-state setpoint relay supports direct ventilation control.

Specifications sourced from the Datasheet rev. 5/28/2024 (Senva doc #152-0381-0C).

Made in the USASenva builds the CT1D in Beaverton, Oregon. The CT1D series is listed on Senva's 2026 Buy America / BABAA / TAA Commerce Declaration (updated 04/21/2026), with domestic content exceeding 65%. Backed by an industry-leading 7-year limited warranty on electronics. ZOT Supply is an authorized Senva distributor; units ship factory-fresh with the full manufacturer warranty.

Key Features

Self-Calibrating NDIRNon-dispersive infrared CO2 element with selectable Automatic Baseline Correction (ABC) that tracks low ambient CO2 to compensate for long-term IR-source aging.
15+ Year Sensor LifeField-replaceable NDIR CO2 element rated for 15+ years of service for low total lifetime cost.
LCD + Push-Button MenuOn-board display and menu let you set scaling (2000/5000/10000 ppm), calibration mode, offset, and high/low setpoints in the field without tools.
Adjustable Setpoint RelaySolid-state relay (1A @ 30VAC/DC, N.O.) with field-settable on/off thresholds for standalone demand-controlled ventilation.
Selectable Analog OutputsDual 3-wire output: 4-20mA plus 0-5V or 0-10V, selectable in the field to match your controller.
Active Temperature TransmitterSecond analog output for temperature with selectable 0-50C or -40-60C range and +/-0.5C accuracy; temperature is shown on the LCD when equipped.

Technical Specifications

Carbon Dioxide (CO2)
Sensing ElementNon-Dispersive Infrared (NDIR)
Output Scaling0-2000 / 0-5000 / 0-10000 ppm (selectable)
Accuracy (Standard)+/-(30 ppm + 3% of reading), 400-2000 ppm; +/-(50 ppm + 5%), 2000-5000 ppm; +/-(100 ppm + 10%), 5000-10000 ppm (at -10 to 50C, 0-85% RH)
Drift (ABC disabled)35 ppm/month
Auto-Calibration (ABC)Selectable ON/OFF (default ON)
Pressure Dependency+1% of reading per kPa from nominal (101 kPa)
Response Time60 s to 90% of reading
Sample / Update Rate1 s / 1 s
CO2 Element Life15+ years
Setpoint (LCD)SPH 500 ppm to full-scale (800 default); SPL 400 ppm to full-scale-50 (700 default)
Temperature (Active Transmitter)
Output Range0-50C (32-122F) or -40-60C (-40-140F), DIP selectable
Accuracy+/-0.5C max from -10 to 50C; +/-0.2C typ 0 to 65C
Resolution / Repeatability0.01C / 0.04C
Response Time>2 s
LCD Temperature DisplayYes
Setpoint Relay
TypeSolid-state, 1A @ 30VAC/DC, N.O.
Power & Enclosure
Power Supply24 VAC 100 mA max / 12-30 VDC 50 mA max (15-30 VDC or 24 VAC required for 0-10V output)
EnclosureABS / Polycarbonate, IP20 / NEMA 1, duct mount
Operating Environment14 to 122F (-10 to 50C), 0-95% RH non-condensing
Dimensions4.0 in H x 4.4 in W x 2.1 in D, plus 6.8 in probe

Documentation

Related Products

Frequently Asked Questions

What CO2 ranges does the CT1D-B3D support?

With the LCD/menu it is field-selectable between 0-2000, 0-5000, and 0-10000 ppm; the factory default is 0-2000 ppm.

Does the CT1D-B3D auto-calibrate?

Yes. The NDIR element uses selectable Automatic Baseline Correction (ABC) that tracks low ambient CO2 to offset long-term sensor drift. For continuously occupied spaces or greenhouses, Senva recommends the dual-channel option instead of disabling ABC.

Will the CT1D-B3D display temperature on the LCD?

Yes. The B (transmitter) option drives an analog temperature output and shows temperature on the LCD when the display is equipped. Temperature range is DIP-selectable for 0-50C or -40-60C.

Is the CT1D-B3D made in the USA?

Yes. Senva manufactures the CT1D in Beaverton, Oregon, and the CT1D series is listed on Senva's 2026 Buy America / BABAA / TAA Commerce Declaration with domestic content exceeding 65%.

What is the warranty on the CT1D-B3D?

Senva backs the CT1D with an industry-leading 7-year limited warranty on the electronics; the NDIR sensing module carries a 3-year warranty.

Warranty

Senva backs the CT1D-B3D with an industry-leading 7-year limited warranty on the electronics. The NDIR CO2 sensing module carries a 3-year warranty. The field-replaceable CO2 element keeps total lifetime cost low across the sensor's 15+ year service life.

ZOT Supply is an authorized Senva distributor; your CT1D ships factory-fresh with the full Senva warranty. Warranty covers defects in materials and workmanship under normal use and service. Refer to Senva's published warranty terms for full conditions and exclusions.

Sensor Type:
Duct Mount
CO2 Element:
Yes
Temperature Element:
Transmitter (Active)
Humidity Element:
None
VOC:
No
Display:
LCD Display
CO2 Range:
2000/5000/10000ppm Selectable
Supported Protocols:
None
Country of Origin:
USA