Senva TGD-BCX-AS : Duct Mount Toxic Gas CO Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, Solid/Opaque Enclosure, 7-Year Warranty

Senva

MSRP: $918.23
$367.25
(You save $550.98 )
(No reviews yet) Write a Review
SKU:
TGD-BCX-AS
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

Senva TGD-BCX-AS : Duct Mount Toxic Gas CO Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, Solid/Opaque Enclosure, 7-Year Warranty

The Senva TGD-BCX-AS is a duct-mounted toxic gas carbon monoxide (CO) sensor/controller featuring BACnet MS/TP, Modbus RTU, and Modbus ASCII output capabilities. It includes an LCD display with a solid/opaque enclosure, all backed by a 7-year warranty. The TGD-BCX-AS finds applications in ensuring adequate airflow in occupied spaces, making it ideal for parking lot garages. It serves to alert occupants of elevated gas levels and enables the direct control of exhaust fans. The specifications include a power supply of 15-30VDC/24VAC, BACnet/Modbus protocol over RS-485, selectable baud rates, fan relay with setpoints, alarm relay with setpoints, a 3-1/2 digit LCD display indicating CO and NO2 levels, LED indicators for normal, warning/fan relay, and alarm/alarm relay statuses. An audible alarm with a 85dB piezo transducer is present, and the CO sensor performance is based on electrochemical technology.

Applications

  • Ensure adequate air flow in occupied spaces
  • Ideal fo parking lot garages 
  • Alert occupants of elevated gas levels
  • Directly control exhaust fans

Specifications

Power Supply 15-30VDC/24VAC(1), 4W max, 160mA max.
BACnet /Modbus  
Protocol RS-485 BACnet MS/TP, Modbus RTU, Modbus ASCII
Baud Rates 9600, 19200, 38400, 57600, 76800, 115200
Fan Relay  
Fan relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
CO fan relay setpoint 25ppm (default), 0-1000 ppm (menu selectable)
Alarm Relay  
Alarm relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
CO alarm relay setpoint 100ppm (default), 0-1000 ppm (menu selectable)
Display  
3-1/2 digit LCD Indicates CO ppm (menu selectable)
LEDs  
Green, Yellow, Red Green = Normal, Yellow = Warning/Fan Relay, Red = Alarm/Alarm Relay
Audible Alarm Exposure  
85dB Piezo transducer 30 minutes above alarm setpoint per UL2034 (menu selectable)
CO Sensor Performance  
Type Electrochemical
Accuracy ±5% of default range(2) ±5%of reading above 200ppm
Resolution 1ppm
Certifications UL2034 Listed Component
Life expectancy >7 years
Coverage Area 5000-7500 square feet (placed within 50' apart from a Senva TG sensor)
Enclosure (Wall & Duct)  
Material ABS/Polycarbonate
Dimensions 4.0”h x 4.4”w x 2.1”d (+6.8” probe for duct version)
Conduit Opening Tapped 1/2” NPT
Rating IP20
Compliance UL61010-1 Listed UL, cUL, CE

 

Datasheets

pdf logo Senva TG UL Toxic Gas CO-NO2 Sensor Datasheet
pdf logo Senva TG UL Install Manual
pdf logo TG UL Field Calibration Instructions
pdf logo User’s Guide TG Series
pdf logo Buy America Act Certification
pdf logo Engineering Specifications
pdf logo LADBS Acceptance
pdf logo Application Note Detecting Toxic Gases
pdf logo Understanding Cross-Sensitivities
pdf logo Application Note TG Sensor Placement
pdf logo TG UL Series BACnet User Manual
pdf logo New TGD Duct Mount Toxic Gas Sensors
Enclosure Style:
Duct
Gas Element:
Carbon Monoxide
Analog Output:
None
Relay Output:
2 SPDT
Communication:
BACnet/Modbus
Display:
LCD Display