Skip to main content

Senva TGW-ANX-AS : Wall Mount Toxic Gas NO2 Sensor/Controller, 0-10V, 0-5V, 1-5V and 4-20mA Selectable Output, LCD Display, Solid/Opaque Enclosure, 7-Year Warranty

Senva

MSRP: $834.75
$333.75
(You save $501.00 )
(No reviews yet) Write a Review
SKU:
TGW-ANX-AS
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

Senva TGW-ANX-AS : Wall Mount Toxic Gas NO2 Sensor/Controller, 0-10V, 0-5V, 1-5V and 4-20mA Selectable Output, LCD Display, Solid/Opaque Enclosure, 7-Year Warranty

Applications

  • Ensure adequate air flow in occupied spaces
  • Ideal fo parking lot garages 
  • Alert occupants of elevated gas levels
  • Directly control exhaust fans

Specifications

Power Supply 15-30VDC/24VAC(1), 4W max, 160mA max.
Analog Outputs  
Programmable Outputs 0-10V (default), 0-5V, 1-5V and 4-20mA (menu selectable)
NO2 output scaling 0-10ppm (default), 0-30ppm (menu selectable)
Fan Relay  
Fan relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
NO2 fan relay setpoint 1ppm (default), 0-30ppm (menu selectable)
Alarm Relay  
Alarm relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
NO2 alarm relay setpoint 3ppm (default), 0-30ppm (menu selectable)
Display  
3-1/2 digit LCD Indicates NO2 ppm (menu selectable)
LEDs  
Green, Yellow, Red Green = Normal, Yellow = Warning/Fan Relay, Red = Alarm/Alarm Relay
Audible Alarm Exposure  
85dB Piezo transducer 30 minutes above alarm setpoint per UL2034 (menu selectable)
NO2 Sensor Performance  
Type Electrochemical
Accuracy ±5% of default range(3) ±5%of reading above 20ppm
Resolution 0.1ppm
Life expectancy >7 years
Coverage Area 5000-7500 square feet (placed within 50' apart from a Senva TG sensor.)
Enclosure (Wall & Duct)  
Material ABS/Polycarbonate
Dimensions 4.0”h x 4.4”w x 2.1”d (+6.8” probe for duct version)
Conduit Opening Tapped 1/2” NPT
Rating IP20
Compliance UL61010-1 Listed UL, cUL, CE

 

Datasheets

pdf logo Senva TG UL Toxic Gas CO-NO2 Sensor Datasheet
pdf logo Senva TG UL Install Manual
pdf logo TG UL Field Calibration Instructions
pdf logo User’s Guide TG Series
pdf logo Buy America Act Certification
pdf logo Engineering Specifications
pdf logo LADBS Acceptance
pdf logo Application Note Detecting Toxic Gases
pdf logo Understanding Cross-Sensitivities
pdf logo Application Note TG Sensor Placement
pdf logo New TGD Duct Mount Toxic Gas Sensors
 
 
Enclosure Style:
Wall
Gas Element:
Nitrogen Dioxide
Analog Output:
2
Relay Output:
2 SPDT
Communication:
None
Display:
LCD Display

Videos Hide Videos Show Videos