Skip to main content

Senva TGW-ANX-AW : Wall Mount Toxic Gas NO2 Sensor/Controller, 0-10V, 0-5V, 1-5V and 4-20mA Selectable Output, LCD Display, All White Solid Enclosure, 7-Year Warranty

Senva

MSRP: $834.75
$333.75
(You save $501.00 )
(No reviews yet) Write a Review
SKU:
TGW-ANX-AW
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

Senva TGW-ANX-AW : Wall Mount Toxic Gas NO2 Sensor/Controller, 0-10V, 0-5V, 1-5V and 4-20mA Selectable Output, LCD Display, All White Solid Enclosure, 7-Year Warranty

Senva UL Listed TG Series sensors can be ordered as individual CO or NO2 sensors or as a combination CO/NO2 sensor in a shared enclosure. The analog output model features 2 outputs that support daisy chain wiring - multiple sensors may be used in a parallel sequence (0-10V) for cost effective coverage of large areas. The unit can also act as a stand alone controller, utilizing the relay for exhaust fan operation or the output for direct control of a VFD. The BACnet/Modbus model supports BACnet MS/TP & Modbus network communication in one unit. Standard features include network auto-configuration, a programmable fan relay, LED indicators, integrated display and audible alarm.

APPLICATIONS

  • Ensure adequate air flow in occupied spaces
  • Ideal fo parking lot garages 
  • Monitor multiple toxic gases with one mounted unit
  • Alert occupants of elevated gas levels
  • Directly control exhaust fans

Power Supply

 

15-30VDC/24VAC(1), 4W max, 160mA max.

Analog Outputs

2 programmable outputs

0-10V (default), 0-5V, 1-5V and 4-20mA (menu selectable)

CO output scaling

0-200ppm (default), 0-1000ppm (menu selectable)

NO2 output scaling

0-10ppm (default), 0-30ppm (menu selectable)

Temperature output scaling

-20 to 85oC

BACnet /Modbus

Protocol RS-485

BACnet MS/TP, Modbus RTU, Modbus ASCII

Baud Rates

9600, 19200, 38400, 57600, 76800, 115200

Fan Relay

Fan relay characteristics

N.C. 1A@24/30VDC (50/60Hz) (no mains connection)

CO fan relay setpoint

25ppm (default), 0-1000 ppm (menu selectable)

NO2 fan relay setpoint

1ppm (default), 0-30ppm (menu selectable)

Alarm Relay

Alarm relay characteristics

N.C. 1A@24/30VDC (50/60Hz) (no mains conenction)

CO alarm relay setpoint

100ppm (default), 0-1000 ppm (menu selectable)

NO2 alarm relay setpoint

3ppm (default), 0-30ppm (menu selectable)

Display

3-1/2 digit LCD

Indicates CO ppm, NO2 ppm (menu selectable)

LEDs

Green, Yellow, Red

Green = Normal, Yellow = Relay, Red = Alarm

Audible Alarm

Exposure

85dB Piezo transducer

30 minutes above alarm setpoint per UL2034

(menu selectable)

CO Sensor Performance

Type

Electrochemical

Accuracy

±5% of default range(2) ±5%of reading above 200ppm

Resolution

1ppm

Certifications

UL2034 Listed Component

Life expectancy

>7 years

Coverage Area

5000-7500 square feet

NO2 Sensor Performance

Type

Electrochemical

Accuracy

±5% of default range(3) ±5%of reading above 20ppm

Resolution

0.1ppm

Life expectancy

>7 years

Coverage Area

5000-7500 square feet

Carbon Dioxide (CO2)

Type

Non-Dispersive Infrared (NDIR)

Accuracy(4)

±(30ppm +3% of reading) (400-2000ppm), @-10-50°C

±(50ppm +5% of reading) Standard (2000-5000ppm),

±(50ppm+3% of reading) Dual Channel (2000-5000ppm),

±(100ppm+10% of reading) (5000-10000ppm)

Resolution

1 ppm

Life expectancy

15 years

Coverage Area

5000-7500 square feet

Operating Environment

Temperature, continuous

-20 to 50oC

Humidity

15-95% continuous, 0-95% intermittent

Max Elevation

2000m

Enclosure

(Wall & Duct)

Material

ABS/Polycarbonate

Dimensions

4.0”h x 4.4”w x 2.1”d (+6.8” probe for duct version)

Conduit Opening

Tapped 1/2” NPT

Rating

IP20

Enclosure

(Metal)

Material & Enclosure Rating

Powder coated steel/acrylic, NEMA 3R

Dimensions

5.0”h x 4.3”w x 2.25”d

Opening

Dual air vents on bottom of enclosure

Mounting

Pre-drilled for 2x4” electrical box

 

Rating

IP20

Agency

Compliance

UL61010-1 Listed UL, cUL, CE

 

Datasheets

pdf logo Senva TG UL Toxic Gas CO-NO2 Sensor Datasheet
pdf logo Senva TG UL Install Manual
pdf logo TG UL Field Calibration Instructions
pdf logo User’s Guide TG Series
pdf logo Buy America Act Certification
pdf logo Engineering Specifications
pdf logo LADBS Acceptance
pdf logo Application Note Detecting Toxic Gases
pdf logo Understanding Cross-Sensitivities
pdf logo Application Note TG Sensor Placement
pdf logo TG UL Series BACnet User Manual
pdf logo New TGD Duct Mount Toxic Gas Sensors
Enclosure Style:
Wall
Gas Element:
Nitrogen Dioxide
Analog Output:
2
Relay Output:
2 SPDT
Communication:
None
Display:
LCD Display

Videos Hide Videos Show Videos