ACI A/MLP2-010-W-B-B-A-5P : Miniature Low Differential Air Pressure Transmitter, +/-10 in WC Bidirectional, 4-20 mA Output, +/-0.25% Accuracy, DIN Rail or Panel Mount, 5-Point NIST Certificate, 5-Yr Warranty, Made in USA

ACI

MSRP: $12,416.00
$1,241.20
(You save $11,174.80 )
(No reviews yet) Write a Review
SKU:
A/MLP2-010-W-B-B-A-5P
Condition:
New
Availability:
Ships in 3-5 Days
Adding to cart… The item has been added
TypeLow DP / Air
Range+/-10 in WC
DirectionBidirectional
Output4-20 mA
Accuracy+/-0.25% FSO
MountingDIN Rail + Panel
NIST Cert5-Point

The ACI A/MLP2-010-W-B-B-A-5P is part of ACI's MLP2 Series Miniature Low Differential Pressure Transmitter family, configured for a -10 to +10 inch WC bidirectional range with a 4-20 mA output (2-wire loop powered (or 3-wire VAC powered)) and +/-0.25% FSO accuracy. Designed specifically for OEM and high-density panel mounting applications, the MLP2 features an integral 35 mm DIN rail mounting foot (U.S. Patent No. 7,416,421) with both rear and side-mount options, vertically oriented wiring and pressure connections, a de-pluggable 3-position screw terminal block for fast field installation, and a pushbutton zero function on the front cover for in-place offset calibration. Sensing is via a high-accuracy piezoresistive silicon element that reduces warmup shift and minimizes the effect of package stress for superior long-term stability. This unit ships with a 5-Point NIST Certificate (5-Point NIST cert (10%, 30%, 50%, 70%, 90% FSO)) - useful for spec engineers and validation environments (clean rooms, isolation rooms, pharmaceutical, semiconductor fabs) where traceable calibration documentation is required. Made in USA by ACI in Middleton, Wisconsin.

Best For

This range is best suited for standard HVAC duct and air-handler pressure measurements: duct static pressure, VAV box differential, filter loading on commercial AHUs, fan inlet/outlet pressure drop, RTU economizer logic, and air-flow measurement via pitot tube (paired with ACI A/PT or A/VPT pitot tubes). Bidirectional mode (output centered at mid-scale: 12 mA, 2.5 V, or 5 V at 0 differential) is required for applications where flow can reverse - reversible-flow systems, makeup-air systems with mode-switching, or balance work where the operating sense flips between modes. Applications listed by ACI: building and duct static pressure, filter monitoring, air flow measurement, process control, roof-top units, air handlers, clean rooms, isolation rooms, and data centers.

5-YEAR WARRANTY
MADE IN USA
5-PT NIST CERT
Backed by ACI's 5-Year Limited Warranty. Manufactured in Middleton, Wisconsin, USA, with factory NIST-traceable calibration on every unit. ZOT Supply is an authorized ACI distributor with fast nationwide and international shipping - every unit ships factory-calibrated with full warranty support. NIST Certificate of Calibration is included with this SKU, documenting calibration measurements traceable to NIST standards.

Key Features

Engineered for OEM & High-Density Panels

The MLP2 is purpose-built for OEM and panel-density applications: integral 35 mm DIN rail mounting foot (U.S. Patent No. 7,416,421) with both rear-mount (integrated) and side-mount (included adapter, much thinner profile) options, vertically oriented wiring and pressure connections, and a de-pluggable 3-position screw terminal block that accepts 14-24 AWG wire. The compact 4.21" x 2.085" x 1.354" footprint and 0.17 lb weight pack significant capability into minimum panel space.

Piezoresistive Silicon Sensing Element

A micro-machined piezoresistive silicon element senses differential pressure with a linear analog output proportional to the specified range. The silicon technology reduces warmup shift compared to older diaphragm-based designs and minimizes the effect of package stress on the sensing element - dramatically improving long-term stability versus competing low-pressure sensor technologies.

4-20 mA Output Signal

4-20 mA current output, available as 2-wire loop-powered (16-36 VDC at 250 ohm load, 21-36 VDC at 500 ohm load) or 3-wire VAC-powered (24 VAC). Output is limited to 20.5 mA maximum. Current output is preferred for long cable runs (over ~150 ft) or in electrically noisy environments near VFDs.

+/-0.25% FSO Accuracy

Accuracy specification includes hysteresis, linearity, and repeatability at 71 deg F (21.5 deg C) typical. This SKU is the enhanced +/-0.25% accuracy variant. +/-0.25% FSO is the enhanced accuracy class - useful for applications where you need tighter control limits or where the reading is being used for verification rather than just monitoring (clean room cert, pharma, semi-fab). Thermal effects: +/-0.056% FSO per deg F relative to 77 deg F (25 deg C).

Front-Cover Pushbutton Zero

A front-cover pushbutton ZERO performs in-place offset calibration without opening the cover. Procedure: ensure no pressure at either HI/LO fitting (or short them together with a tubing loop), hold the ZERO button for 5 seconds, then release. Recommended after the 15-minute warmup period or after re-positioning the unit. Periodic re-zeroing eliminates the effect of long-term drift, which is primarily an offset shift rather than a span shift.

5-Point NIST Certificate Included

This SKU ships with a 5-Point NIST cert (10%, 30%, 50%, 70%, 90% FSO), documenting measurements at 10%, 30%, 50%, 70%, and 90% of full scale output, with all measurements traceable to NIST standards. The 5-point cert provides finer characterization of sensor linearity across the range - preferred for pharmaceutical, semiconductor, and regulated environments where audit-trail rigor matters. The certificate is shipped with the unit; digital copies can be requested through ZOT Supply.

Stable Calibration with Pushbutton Re-Zero

The MLP2 uses a digital pot for Span calibration (factory-set, not user-adjustable - units requiring re-calibration must be returned to ACI). Long-term drift is primarily a function of stress relaxation over time in the silicon package, which shifts the offset (not the span). Periodic re-zeroing via the pushbutton eliminates this drift component without service interruption.

Robust Overpressure Protection

Proof pressure of 350 inch WC (87.12 kPa) and burst pressure of 550 inch WC (136.9 kPa) - far above the maximum operating range of this SKU. Tolerates transient overpressure events from duct dampers slamming closed, fan start-up surges, and HVAC commissioning test pressures without sensor damage or calibration drift. Note: media must be non-corrosive, non-ionic gases (dry air or inert gases) - liquids and corrosive vapors will damage the silicon sensing element.

Brass Push-On Pressure Fittings

Two brass push-on pressure fittings (HI and LO) accept 0.25" (6.35 mm) O.D. x 0.170" (4.318 mm) I.D. flexible poly tubing - standard HVAC pressure-sensing tubing. ACI recommends a maximum tubing length of 75 feet (23 meters); longer runs introduce signal lag and reduce response time. Pair with ACI's pitot tube accessories (A/PT, A/SPT, A/VPT) or pickup ports (A/SP-PUP, A/R-PUP) for sealed-tap applications.

De-Pluggable Terminal Block

The 3-position de-pluggable screw terminal block accepts 14 AWG (1.628 mm²) to 24 AWG (0.5105 mm²) wire with 4.43-5.31 in-lb torque. The de-pluggable design lets technicians pre-wire the panel offline, then plug the terminal block into the unit - dramatically reducing in-panel labor on OEM builds. Pin assignments: VIN / GND / OUT. ACI recommends shielded cable with the shield grounded only at the controller end (single-ended grounding prevents ground loops).

Technical Specifications

SpecificationDetail
Sensor StyleActive differential pressure transmitter for low-pressure air
Sensing ElementPiezoresistive silicon (micro-machined)
Measured ValueDifferential pressure (HI - LO ports)
Pressure Range-10 to +10 inch WC (Bidirectional)
Output Signal4-20 mA - 2-wire loop powered (or 3-wire VAC powered), output limited to 105% of full scale
Accuracy+/-0.25% FSO (includes hysteresis, linearity, repeatability at 71 deg F)
Thermal Effects+/-0.056% FSO per deg F (+/-0.10% FSO per deg C) relative to 77 deg F
Warm-Up Time15 minutes (recommended before zeroing)
Response Time (T95)4 seconds
Output Update Rate500 ms
Zero FunctionFront-cover pushbutton ZERO (hold 5 sec to re-zero)
Proof Pressure350 inch WC (87.12 kPa)
Burst Pressure550 inch WC (136.9 kPa)
Power Supply16-36 VDC (250 ohm load) / 21-36 VDC (500 ohm load) / 24 VAC +/-10% 50/60 Hz
Supply Current23 mA minimum (0.83 VA power consumption)
Operating Temperature32 to 185 deg F (0 to 85 deg C)
Compensated Temperature Range32 to 122 deg F (0 to 50 deg C)
Storage Temperature-40 to 176 deg F (-40 to 80 deg C)
Operating / Storage Humidity10-95% RH non-condensing
Media CompatibilityNon-corrosive, non-ionic gases (dry air, inert gases)
Pressure FittingBrass push-on, accepts 0.25" O.D. x 0.170" I.D. flexible poly tubing
Mounting35 mm DIN rail (rear or side mount) + #8 x 3/4" panel screws (U.S. Patent No. 7,416,421)
Wiring3-position de-pluggable screw terminal block, 14-24 AWG, 4.43-5.31 in-lb torque
EnclosurePolycarbonate UL 94 V-0, operating -40 to 248 deg F (-40 to 120 deg C)
Dimensions4.21" x 2.085" x 1.354" (106.94 x 52.96 x 34.04 mm)
Weight0.17 lb (0.078 kg)
NIST Calibration5-Point NIST Certificate - 5-Point NIST cert (10%, 30%, 50%, 70%, 90% FSO)
ApprovalsCE, RoHS2, WEEE, REACH, UKCA
ManufacturerACI (Automation Components, Inc.) - Middleton, WI USA
Manufacturer Part NumberA/MLP2-010-W-B-B-A-5P
Warranty5-Year ACI Limited Warranty

What's In the Box

Included
  • MLP2 transmitter with integral rear-mount 35 mm DIN rail foot
  • Side-mount DIN rail adapter clip (for thinner-profile high-density panel mounting)
  • De-pluggable 3-position screw terminal block (pre-installed)
  • Two (2) #8 x 3/4" self-drilling panel-mount screws
  • Installation & Operation Instructions (ACI document I0000791)
  • 5-Point NIST Certificate - documenting calibration measurements traceable to NIST standards
Accessories (Sold Separately)

Documentation

Frequently Asked Questions

What does the A/MLP2-010-W-B-B-A-5P measure and output?

It measures differential air pressure in the -10 to +10 inch WC range (bidirectional) and outputs a linear 4-20 mA analog signal proportional to the pressure. Accuracy is +/-0.25% FSO including hysteresis, linearity, and repeatability. The MLP2 is intended for HVAC and OEM applications using dry air or other non-corrosive, non-ionic gases - not liquids, refrigerants, or corrosive vapors.

Should I use inches WC or Pascal units?

Inches of Water Column (WC) is the standard in North American HVAC; Pascals (Pa) is used internationally and in scientific or European-spec applications. The MLP2 is range-specific - this SKU is calibrated in inches WC. For Pascal calibration on smaller ranges, see the matching variants with unit code P (note: smaller Pa ranges like 50, 100, 300 Pa are Pascal-only because they're below the equivalent WC range boundary).

When do I need bidirectional mode?

Bidirectional mode is required when the differential pressure can swing both positive and negative across zero - reversible-flow heat recovery, makeup-air systems with mode switching, or isolation rooms that need to flip between positive (protective) and negative (containment) pressure. In bidirectional mode, 0 differential = 50% of output range (12 mA, 2.5 V, or 5 V depending on output type). For one-direction-only applications, the unidirectional variants give you full range resolution on the relevant direction.

When and how should I zero the device?

Zero on initial installation, after re-positioning the unit, and any time the unit reads a non-zero offset with no pressure applied. Procedure: (1) Wait at least 15 minutes after power-up (warm-up period). (2) Ensure no pressure at the HI or LO fittings - either disconnect both tubes from the process or connect a short tubing loop between the two brass fittings to neutralize external pressure. (3) Press and hold the ZERO button for 5 seconds, then release - the unit enters zero mode after the button is released. The Span calibration is digital and factory-set; units requiring Span recalibration must be returned to ACI.

How do I mount this on a DIN rail?

The MLP2 offers two DIN rail options: rear mount (integrated into the enclosure - just clip the unit onto the rail with the integral foot) or side mount (uses the included adapter clip for a thinner-profile installation in high-density panels). To install the side-mount clip: pry off the front cover with a flat-blade screwdriver on the upper edge or side slots, slide the clip into position, then snap the front cover back into place. Both options are 35 mm DIN rail compatible (U.S. Patent No. 7,416,421). For panel-screw mounting, use the two included #8 x 3/4" self-drilling screws through the top and bottom flanges.

What does the 5-Point NIST Certificate include?

The 5-Point NIST cert (10%, 30%, 50%, 70%, 90% FSO) documents the calibration measurements performed on this specific unit, with all measurements traceable to NIST standards. The 5-point cert documents readings at 10%, 30%, 50%, 70%, and 90% of full scale output - providing finer characterization of sensor linearity across the range. Preferred for pharmaceutical, semiconductor, and other regulated environments where audit-trail rigor matters. The certificate ships with the unit; digital copies can be requested through ZOT Supply.

What accessories do I need for installation?

Required: pressure-sense tubing (0.25" OD x 0.17" ID medical-grade PVC - ACI offers A/10' TUBE, A/20' TUBE, A/50' TUBE, A/100' TUBE), 14-24 AWG shielded cable for the wiring, and a 24 VAC or 12-36 VDC power supply. Application-dependent: pitot tubes for air-flow measurement (PT 3", PT 5.2", PT 7.5", PT 9.7" with foam gaskets; SPT-3.5" / SPT-8.0" static tips; VPT / VPT-8" velocity tips), pickup ports for wall/room pressure taps (A/SP-PUP stainless, A/R-PUP beige, A/R2-PUP white, or A/O-PUP-H / A/O-PUP-V outdoor weatherproof), and isolation/equalization valves if the install requires them. Keep tubing runs to a maximum of 75 feet (23 meters) to maintain response time.

How does the MLP2 compare to Belimo's 22ADP?

Both are active differential air pressure transmitters. MLP2 advantages: smaller form factor (designed for OEM/panel density), DIN rail mounting (rear or side), front-cover pushbutton zero, optional 3-point or 5-point NIST Certificate of Calibration, Made in USA, lower price point. Belimo 22ADP advantages: Modbus RTU communication (on -55x and -56x variants), 8 DIP-selectable sub-ranges on a single SKU (vs MLP2's fixed single range), volumetric flow output, optional LCD display, NEMA 4X/IP65 enclosure (MLP2 is indoor-only), UL 2043 plenum rating. Choose MLP2 for panel-density OEM applications with documented NIST certification; choose Belimo 22ADP for Modbus integration, multi-range stocking flexibility, or wash-down/outdoor installations.

What media can this sensor handle?

Dry air and inert non-conductive gases only: clean ambient air, nitrogen, argon, CO2 (dry). The MLP2 is NOT compatible with: liquids (any form), refrigerants, corrosive gases (chlorine, ammonia, hydrogen sulfide, acid fumes), conductive gases, condensing moisture, or any media containing particulates. Liquid contamination at the sensor diaphragm causes immediate damage and voids the warranty. For wet/wet differential pressure applications, see Senva PW30 or Belimo 22PDP/22WDP series in the Liquid Pressure subcategory.

Series:
MLP2
Pressure Range:
-10 to +10 inch WC
Range Class:
Medium
Direction:
Bidirectional
Output Signal:
4-20 mA
Accuracy:
+/-0.25% FSO
Display:
No
NIST Certificate:
5-Point
Mounting:
DIN Rail / Panel
Made in USA:
Yes