Dent Instruments PS12HD-P-D-N-T : PowerScout 12 HD Multi-Circuit Power Submeter, 12-Channel, BACnet/Modbus, Mounting Plate with Display, TOU Enabled

Dent Instruments

MSRP: $2,210.00
Your Price:  $1,482.00
(You save $728.00 )
(No reviews yet) Write a Review
SKU:
PS12HD-P-D-N-T
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
Channels12 Channels
Service1Φ / 3Φ (WYE & Delta)
CapacityUp to 4 x 3Φ / 12 x 1Φ
AccuracyANSI C12.20-2010 Class 0.2
ProtocolsBACnet & Modbus
ConnectivityEthernet + RS-485
MountingMounting Plate
DisplayYes (4-line tri-color)

PS12HD-P-D-N-T — PowerScout 12 HD Multi-Circuit Power Submeter

The Dent Instruments PS12HD-P-D-N-T is the PowerScout™ 12 HD, DENT's networked 12-channel, three-phase submeter. The PS12HD-P-D-N-T measures voltage, current, power, energy, and many other electrical parameters on any combination of single- and three-phase loads — up to 4 three-phase or 12 single-phase circuits — and can network with other PowerScout HD meters to cover multiple loads across a facility.

Looking ahead? The PowerScout FLEX 12 is DENT's next-generation replacement for the PowerScout HD — faster commissioning with FLEXPoint™, browser-based FLEXPoint™ GO, flexible Virtual Meters, and 7.2 kHz sampling.

See the PowerScout FLEX 12 →

The PS12HD-P-D-N-T delivers revenue-grade performance with 1.8 kHz sampling, a 1-second update rate, and ANSI C12.20-2010 Class 0.2 accuracy (depending on CT). It supports both Modbus (SunSpec IEEE-754) and BACnet over RS-485 or Ethernet, includes four digital pulse inputs, and provides a 12 VDC auxiliary output. DENT's patented PhaseChek™ circuitry (U.S. Patent 7,612,552) confirms correct CT orientation during commissioning.

This model is TOU (Time-of-Use) enabled: the PS12HD-P-D-N-T tracks energy against tariff schedules using ViewPoint HD, supporting up to 3 tariffs, 6 schedules, and 4 seasons with holiday handling, and stores accumulated kWh and peak kW per tariff (with reset timestamps) for accurate, schedule-aware cost recovery.

Built as a UL-Recognized circuit board on a mounting plate, the PS12HD-P-D-N-T is delivered in the Mounting Plate configuration and is configured through ViewPoint HD PC software or a web browser. It operates as an endpoint reporting to a building management system, RTU, data acquisition device, or DENTCloud™ host.

Best for

  • High-density tenant and accountability submetering — up to 12 circuits from one device
  • Bi-directional metering and demand-response monitoring
  • Real-time power monitoring of building mains and equipment loads
  • Tariff-aware cost recovery across peak, off-peak, and seasonal rates
  • Projects requiring Made in USA / BAA / TAA equipment

Key Features

Time-of-Use (TOU) Enabled

The PS12HD-P-D-N-T tracks energy against utility tariff schedules in ViewPoint HD — up to 3 tariffs, 6 schedules, and 4 seasons with holiday handling — and reports accumulated kWh and peak kW per tariff with reset timestamps.

Revenue-Grade Accuracy + PhaseChek™

The PS12HD-P-D-N-T meets ANSI C12.20-2010 Class 0.2 revenue-grade accuracy (dependent on CT) with NIST-traceable calibration, and patented PhaseChek™ circuitry (U.S. Patent 7,612,552) flags mis-phased or backwards CTs during commissioning.

Dual-Protocol + 4 Pulse Inputs

The PS12HD-P-D-N-T communicates over Modbus (SunSpec IEEE-754) or BACnet using RS-485 or Ethernet (Modbus RTU, BACnet MS/TP, Modbus TCP, or BACnet IP) and adds four digital pulse inputs for gas, water, or other meters.

12 Channels, One Device

Meter up to 4 three-phase or 12 single-phase circuits across two voltage references from a single PS12HD-P-D-N-T, reducing hardware and panel space versus single-circuit meters.

ViewPoint HD Setup

Configure the PS12HD-P-D-N-T from ViewPoint HD or a web browser, scan the network to find and name every PowerScout HD meter, and pre-build configuration templates — even without the meter on hand — for fast, repeatable deployment.

Universal CT Compatibility

Use the PS12HD-P-D-N-T with DENT 333 mV Split Core or RōCoil™ (Rogowski) CTs, including revenue-grade options, measuring up to 4000 A depending on the CT selected.

Technical Specifications

SpecificationPS12HD-P-D-N-T
Model / Part NumberPS12HD-P-D-N-T
SeriesPowerScout 12 HD (12-channel, 3-phase)
Channel CapacityUp to 4 three-phase or 12 single-phase circuits
Service TypeSingle Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta)
PowerFrom L1 Phase to L2 Phase. 90-600 VAC RMS, CAT III, 50/60 Hz, 500 mA AC Max
Auxiliary Power OutUnregulated 12 VDC, 200 mA, self-resetting fuse (requires 100 VAC minimum input)
AC Protection0.5 A fuse, 200 kA interrupt capacity
Voltage Channels90-346 VAC Line-to-Neutral, 600 V Line-to-Line, CAT III
Current Channels12 channels, 0.525 VAC max, 333 mV CTs, 0-4000 A depending on CT
Maximum Current Input150% of CT rating (mV CTs) to maintain accuracy; up to 4000 A with RōCoil CTs
Pulse Inputs4 inputs, 3.3 V sourcing (current limited) to a dry-contact pulse output; max 10 Hz (50 ms min transition)
Measurement TypeTrue RMS using high-speed DSP with continuous sampling
Accuracy0.2% — ANSI C12.20-2010 Class 0.2; NIST traceable calibration
Resolution32-bit IEEE-754 single-precision floating point
Line Frequency50/60 Hz (45-70 Hz measurable range); measured L1-N
Waveform Sampling1.8 kHz
Parameter Update Rate1.0 second
Time-of-Use (TOU)Up to 3 tariffs, 6 schedules, and 4 seasons with holiday handling via ViewPoint HD; per-tariff accumulated kWh and peak kW with reset timestamps
MeasurementsVolts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import/Export/Net kWh, kVAh and kVARh, THD, Theta, Frequency — per phase and element total
Display4-line LCD with tri-color backlight
Communications HardwareRS-485, Ethernet, and USB (USB for configuration only)
Supported ProtocolsModbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP (Modbus based on SunSpec IEEE-754)
Communication Rate9600 (default), 19200, 38400, 57600, 76800, 115200 baud
Max Communication Length1200 m at 100K bits/second or less
Alarm OutputUndervoltage (open collector, 30 VDC max)
Web Page Security2 levels of PIN protection (Read/Write or Read-Only)
MountingOpen circuit board on a mounting plate for installation in the UL-approved enclosure of your choice
High-Voltage CoverNot included on mounting-plate version
EnclosureABS plastic, 94-V0 flammability rating; 1 in EMT conduit connections
Dimensions17.8 x 26.3 x 8.0 cm (7.0 x 10.4 x 3.1 in)
Wire Connections12-28 AWG, 600 VAC; voltage connection must be #14 AWG or larger and 600 VAC rated
Operating Temperature-20 to 60 °C (-4 to 140 °F)
Humidity5% to 95% non-condensing
CertificationsUL Recognized (E186827, UL 61010-1 3rd Ed.; CSA C22.2 No. 61010-1); CE (LVD EN61010-1, EMC EN61326-1); RoHS 2 (EN50581); ANSI C12.20 Class 0.2; Made in USA; BAA and TAA compliant
Configuration SoftwareViewPoint HD (Windows 7 / 8 / 10 / 11) and web browser

Documentation

Frequently Asked Questions

How many circuits can the PS12HD-P-D-N-T meter?

The PS12HD-P-D-N-T has 12 current channels and can meter up to 4 three-phase or 12 single-phase circuits, networked with other PowerScout HD meters to cover multiple loads across a facility.

What protocols does the PS12HD-P-D-N-T support?

The PS12HD-P-D-N-T supports Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP (Modbus based on SunSpec IEEE-754) over RS-485 or Ethernet, plus four digital pulse inputs.

Which current transformers work with the PS12HD-P-D-N-T?

The PS12HD-P-D-N-T uses DENT 333 mV Split Core or RōCoil™ (Rogowski) CTs, including revenue-grade options, and measures up to 4000 A depending on the CT selected.

What is the form factor of the PS12HD-P-D-N-T?

The PS12HD-P-D-N-T is supplied as a UL-Recognized circuit board on a mounting plate in the Mounting Plate configuration, measuring 17.8 x 26.3 x 8.0 cm (7.0 x 10.4 x 3.1 in).

Is the PS12HD-P-D-N-T revenue grade?

The PS12HD-P-D-N-T meets ANSI C12.20-2010 Class 0.2 revenue-grade accuracy, dependent on the CT selected, and ships with a NIST-traceable calibration.

How does Time-of-Use work on the PS12HD-P-D-N-T?

Using ViewPoint HD you can set up to 3 tariffs, 6 schedules, and 4 seasons with holiday handling on the PS12HD-P-D-N-T, then view and reset accumulated kWh and peak kW per tariff with timestamps.

What is the difference between the PS12HD-P-D-N-T and the PowerScout FLEX 12?

The PowerScout FLEX 12 is the next-generation replacement for the PowerScout 12 HD, adding FLEXPoint™ setup tools, browser-based FLEXPoint™ GO, Virtual Meters, and 7.2 kHz sampling. The PS12HD-P-D-N-T remains available; if you are specifying a new system, consider the FLEX 12.

Is the PS12HD-P-D-N-T Made in USA?

Yes. Per the DENT data sheet the PowerScout 12 HD, including the PS12HD-P-D-N-T, is Made in USA and is marked BAA and TAA compliant.

Brand:
DENT Instruments
Series:
PowerScout 12 HD
Meter Type:
3-Phase Networked
Current Channels:
12
Mounting:
Mounting Plate
Display:
Yes
Connectivity:
Ethernet and RS-485
Supported Protocols:
Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP
Accuracy Class:
ANSI C12.20-2010 Class 0.2
Country of Origin:
Made in USA
Time of Use:
TOU Enabled