Skip to main content

Senva CT1O-E3D : Outdoor Temperature/CO2 Sensor, 10K Type II Thermistor, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, LCD Display, 7-Year Limited Warranty

Senva

MSRP: $667.80
$264.00
(You save $403.80 )
(No reviews yet) Write a Review
SKU:
CT1O-E3D
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

Senva CT1O-E3D : Outdoor Temperature/CO2 Sensor, 10K Type II Thermistor, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, LCD Display, 7-Year Limited Warranty

Featuring a gold plated dual-channel NDIR sensor for the best accuracy and the highest reliability for your outdoor or greenhouse sensing needs.  An optional built-in LCD display makes set up a snap, and a standard solid-state setpoint relay makes demand ventilation simple. Dual 4-20mA and 0-10/5 vdc outputs.  

Features

  • Integrated display and push-button menus for field selectable scale, calibration, and operational modes
  • Dual 4-20mA and 0-5V/0-10V output (jumper selectable)
  • Integrated high-reliability solid-state set-point relay is ideal for direct control applications; easy to set up thanks to LCD
  • Non-dispersive infrared sensing element (NDIR)
  • Field replaceable dual-channel CO2 sensor
  • 15+ year life expectancy on CO2 sensing element
  • Industry leading 7-year limited warranty on electronics; NDIR module 3 years
  • ±30ppm, ±3% of reading

Specifications

Power Supply 12-30VDC/24VAC(1), 100mA max.
Dual Analog 3-wire 4-20mA and 0-5V/0-10V (2) (jumper)
Output scaling 0 - 2000 or 0 - 5000 ppm (selectable)
Digital Setpoint Output Solid-state, 1A @ 30VAC/DC, N.O.
Sensor Performance  
Type Non-dispersive Infrared (NDIR)
Accuracy
  • ±30ppm, ±3% of reading (400-2000ppm)
  • ±50ppm, ±5% of reading (2000-5000ppm)
  • Consult Factory for accuracy above 5000ppm
Response time 60 seconds to 90% reading
Output update rate 1 second
LCD Menu Setup Parameters  
SPH, Setpoint, Hi (On point) 500ppm to full-scale (800ppm default)
SPL, Setpoint, Lo (Off point) 400ppm to full-scale-50 (700ppm default)
SCL, Scaling 0-2000ppm, 0-5000ppm, 0-10000ppm (2000ppm default)
ADJ, Adjustment Offset adjustment +/-250ppm (0 default)
CAL, Calibration mode Automatic mode ON or OFF (default=ON)
RUN, Run mode Displays CO2 in ppm
Enclosure ABS/Polycarbonate
Dimensions 4.0’ h x 4.4”w x 2.1”d (+6.8” probe)

 

Datasheets

pdf logo Senva CT1O CO2/Temp Duct Sensor Data Sheet
pdf logo Senva CT1O CO2/Temp Duct Sensor Installation Sheet
pdf logo Senva Dual Channel CO2 for Outdoor and Greenhouse Applications
pdf logo Senva Made In USA Certificate 2023

 

Sensor Type:
Outside Air
Humidity Element:
None
CO2 Element:
Yes
Temperature Element:
10K Type II
Display:
LCD Display
VOC:
No