null Skip to main content

Senva CT1W-B3X Surface-Mount Wall CO2/Temperature Sensor, Temperature Transmitter, No Display, 4-20 mA/0-5/0-10 V

Senva

MSRP: $345.30
Your Price:  $169.19
(You save $176.11 )
(No reviews yet) Write a Review
SKU:
CT1W-B3X
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
CO2 SensingNDIR, Single Channel
CO2 Range0-2000 ppm (factory)
TemperatureActive Transmitter
DisplayNone
Outputs4-20 mA / 0-5 V / 0-10 V
MountingSurface Wall

The Senva CT1W-B3X is a surface-mount room CO2 (carbon dioxide) and temperature sensor with a single-channel NDIR element and a 3-wire 4-20 mA, 0-5 V or 0-10 V output for demand-controlled ventilation. It adds an active temperature transmitter output. This is the no-display version: the CO2 range and calibration settings cannot be changed without the LCD menu, and it has no setpoint relay. The 0-5 V or 0-10 V output is still selected with DIP switch 1, and the temperature scale with DIP switch 2. The LCD version is the CT1W-B3D.

Authorized Distributor

ZOT Supply is an authorized distributor of Senva products.

Where this model fits

Choose the CT1W for surface mounting on a wall. The lid locks at all four snaps, which suits schools and public areas. Mount it vertically at light-switch height on an interior wall, away from supply air, doors, windows and heat sources.

Compare mounting alternatives: CT1R-B3X (recessed wall, single-channel); CT1D-B3X (duct, single-channel); CT1O-B3X (outdoor, dual-channel as standard, a different CO2 channel type from this model). A matching temperature and display code does not make two models interchangeable: check the CO2 channel type and the mounting before substituting.

Single-channel models rely on automatic baseline correction (ABC), which tracks the lowest CO2 level the space reaches. That suits offices, classrooms and other spaces that empty out regularly. For spaces occupied around the clock, Senva recommends a dual-channel model.

The B option is an active transmitter: temperature leaves the sensor as a 4-20 mA or voltage signal on its configured temperature scale, so use it when the controller has an analog temperature input. If the controller reads a thermistor or RTD directly, pick a passive C, D, E, F or K model instead.

Warranty and origin

Senva covers the CT1 series with a 7-year limited warranty. ZOT Supply is an authorized Senva distributor. See Senva's published warranty terms for conditions and exclusions.

Senva describes its CT1 room sensors as made in the USA. The CT1W series is not named on Senva's 2026 commerce declaration, so ask Senva for written confirmation if your project needs BABAA, TAA or Buy American documentation.

Key facts

  • Single-channel NDIR with automatic baseline correction (ABC). Accuracy ±(30 ppm + 3% of reading) from 400 to 2000 ppm.
  • CO2 range: 0-2000 ppm factory range. Changing the range requires the LCD version.
  • Temperature: active transmitter; the analog scale is set with DIP switch 2 to 10 to 35°C or 0 to 50°C.
  • CO2 setpoint relay: none on this no-display model.
  • Power: 24 VAC (100 mA max) or 12-30 VDC (50 mA max). The 0-10 V output needs 15-30 VDC or 24 VAC.

Specifications

Manufacturer part numberCT1W-B3X
CO2 sensing elementNon-dispersive infrared (NDIR), single-channel
CO2 output scaling0-2000 ppm factory range. Changing the range requires the LCD version.
CO2 accuracy at the 0-2000 ppm output±(30 ppm + 3% of reading), 400-2000 ppm, -10 to 50°C
Drift with ABC disabled35 ppm/month; may vary with environment
Automatic calibration (ABC)On at the factory; it cannot be changed without the LCD version.
CO2 response time60 s to 90% of reading; output updates every 1 s
Analog outputs3-wire 4-20 mA and 0-5 V / 0-10 V. DIP switch 1 selects 0-5 V or 0-10 V.
TemperatureActive transmitter on the analog output: 10 to 35°C or 0 to 50°C, selected with DIP switch 2. Accuracy better than ±0.2°C, resolution 0.01°C, element range -40 to 60°C (-40 to 140°F).
CO2 setpoint relayNone. Senva fits the setpoint relay only on display models.
DisplayNone. The CO2 range, offset adjustment and automatic calibration setting are LCD menu settings and cannot be changed on this model. DIP switch 1 still selects the 0-5 V or 0-10 V output; DIP switch 2 still selects the temperature scale.
Power supply24 VAC, 100 mA max, or 12-30 VDC, 50 mA max. The 0-10 V output requires 15-30 VDC or 24 VAC. Senva recommends a dedicated transformer for AC supply.
Operating environment-10 to 50°C (14 to 122°F), 0-95% RH non-condensing
EnclosureABS plastic, IP20 / NEMA 1
Dimensions5.66 in H x 3.0 in W x 1.07 in D (surface mount, per Senva datasheet)
WarrantySenva 7-year limited warranty

Documents

Frequently asked questions

What CO2 range does the CT1W-B3X output?

It ships scaled 0-2000 ppm, and that range cannot be changed in the field. The 0-5000 and 0-10,000 ppm ranges need the LCD version (CT1W-B3D).

How does the CT1W-B3X report temperature?

As an analog signal from the built-in transmitter, on the scale configured with DIP switch 2: 10 to 35°C or 0 to 50°C. The controller needs an analog input for it, not a thermistor input.

Does the CT1W-B3X have a CO2 setpoint relay?

No. Senva fits the setpoint relay only on display models, such as the CT1W-B3D.

Does the CT1W-B3X need field calibration?

Senva calibrates it at the factory and does not recommend routine field calibration. Automatic baseline correction (ABC) tracks low ambient CO2 to correct long-term drift.

Related CT1 models

  • CT1W-B3D: same sensor with LCD and setpoint relay
  • CT1W-A3X: CO2 only, no temperature element
  • CT1W-E3X: 10K Type II Thermistor

Specifications are taken from Senva's CT1W installation manual 152-0410-0D (rev. 5/24/2024) and the Senva CT1R / CT1W datasheet. Where the two differ, the installation manual is used. The instructions shipped with the product take precedence, and specifications may change without notice.

Warranty

Senva 7-year limited warranty. Refer to Senva’s published warranty terms for coverage, conditions and exclusions.

Sensor Type:
Wall Mount
Temperature Element:
Transmitter
Supported Protocols:
None
Humidity Element:
None
CO2 Element:
Yes
Setpoint:
No Setpoint
Override:
No Override
Display:
No Display
Material:
Plastic
Mounting:
Surface
CO2 Channel:
Single Channel
CO2 Range:
2000ppm Fixed
CO2 Setpoint Relay:
None