null Skip to main content

Prolon PL-C1050-FLX : FlexIO Configurable Input/Output Controller, 4 Digital Outputs, 1 Analog Output, 3 Configurable Analog Inputs, 1 Digital Input, Modbus RTU (RS485)

Prolon

Your Price:  $715.72
(No reviews yet) Write a Review
SKU:
PL-C1050-FLX
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
ApplicationFlexIO Controller
Digital Outputs4 triac
Analog Output1
Inputs3 analog, 1 digital
CommunicationModbus RTU (RS485)
Supply24 VAC, Class 2
The Prolon PL-C1050-FLX FlexIO is a general purpose Modbus RTU HVAC controller whose 3 analog inputs and 4 triac outputs are individually configurable for temperature, pressure, gas, current, voltage, level, speed and flow signals.

Specifications on this page are taken from the Prolon FlexIO Controller datasheet, REV 7.3.0 / PL-DATA-C1050FLX-C/F-EN.

The FlexIO is the C1050 that is not tied to a single piece of equipment. Its inputs and outputs are configured individually, so it covers the outlying functions a project needs that no dedicated Prolon controller addresses.

Each of the three analog inputs takes a selectable signal range: thermistor, dry contact, 0-5 VDC, 1-5 VDC, 0.5-4.5 VDC or 0-10 VDC. Scales for pressure and gas inputs are configurable, so almost any field sensor can be scaled into it, and inputs and outputs can be given custom names and display options.

Outputs act on any local input or on data received from a network master. Logic options include on/off, PI loop, direct or reverse acting, and pulsed; outputs can be interlocked with each other, paired with lead/lag and backup, or overridden automatically on outside temperature or occupancy.

Best For

  • HVAC functions no dedicated Prolon controller covers
  • Temperature, pressure, gas, humidity, current, voltage, power, level, speed and flow signals
  • Lighting control driven by up to 5 occupancy states from an NC2000

Key Features

Configurable input signal types

3 analog inputs with individually configurable signal ranges (thermistor, dry contact, 0-5 VDC, 1-5 VDC, 0.5-4.5 VDC, 0-10 VDC) plus 1 digital input.

Wide range of measured types

Input types available include temperature, dry contact, pressure, gas, humidity, current, voltage, power, level, speed and flow.

Flexible output logic

Output logic sequences include on/off, PI loop, direct or reverse acting, and pulsed. Outputs can be interlocked with each other.

Lead/lag and backup pairing

2 outputs can be linked together with lead/lag and backup capabilities.

Occupancy-driven lighting control

Can receive up to 5 different occupancy states from an NC2000, allowing for versatile lighting control.

Fixed or reset setpoints

Outputs can be configured to maintain a fixed setpoint or a variable setpoint based on a reset curve, and can be overridden automatically on outside temperature or occupancy.

Technical Specifications

SpecificationPL-C1050-FLX Value
Supply24 VAC ±10%, 50/60 Hz, Class 2
Power2 VA (consumption), 32 VA (input)
Inputs
  • 3 analog inputs, individually configurable: thermistor, dry contact, 0-5 VDC, 1-5 VDC, 0.5-4.5 VDC, 0-10 VDC
  • 1 digital input
Digital Outputs4 triac outputs, 10-30 VAC source or sink, 300 mA max (resettable fuse)
Analog Output1 output 0-10 VDC / 2-10 VDC / 0-5 VDC, 40 mA max (resettable fuse)
Indication Lights (LED)State of each output / Communication / Power / State of microprocessor
MicroprocessorPIC18F6722, 8 bits, 40 MHz, 128 KB FLASH memory
CasingMolded ABS, UL94-HB
CommunicationModbus RTU (RS485), up to 127 nodes
Baud Rates9600, 19200, 38400, 57600, 76800, 115200
ConnectionRemovable screw-type terminal blocks (16 AWG max)
Dimensions6.2 in x 5.2 in x 2.5 in (157 mm x 132 mm x 64 mm)
Weight0.85 lbs (0.39 kg)
Environment-4 to 122 °F (-20 to 50 °C), non-condensing
CertificationUL916 Energy Management Equipment, CAN/CSA-C22.2, RoHS, FCC part 15: 2012 class B

Documentation

Frequently Asked Questions

What is the PL-C1050-FLX used for?
It is a general purpose HVAC controller for functions that are not covered by a dedicated Prolon controller. Where the rest of the C1050 line targets one piece of equipment and one sequence, the FlexIO does not.
What signal types do the analog inputs accept?
Each of the 3 analog inputs is individually configurable for thermistor, dry contact, 0-5 VDC, 1-5 VDC, 0.5-4.5 VDC or 0-10 VDC. There is also 1 digital input.
Can it be used for lighting control?
Yes. It can receive up to 5 different occupancy states from an NC2000 network controller, which is what makes versatile lighting control possible.
Can two outputs share a load?
Yes. 2 outputs can be linked together with lead/lag and backup capabilities, and outputs can be interlocked with each other.
Does it work stand-alone?
Yes. It operates stand-alone or can be integrated into a Prolon network, and outputs can act on local inputs or on data received from a network master.
Controller Type:
Flexible Input/Output
Digital Outputs:
4
Analog Outputs:
1
Analog Inputs:
3
Digital Inputs:
1
Communication:
Modbus RTU (RS485)

Videos Hide Videos Show Videos