null Skip to main content

Prolon PL-M2000-HYD : Hydronic Controller, Water-To-Water Heat Pump and Tank Sequences, Compressor Lead-Lag, 9 Configurable Analog Inputs, 5 Triac Outputs, 3 Analog Outputs, Modbus RTU (RS485)

Prolon

Your Price:  $1,341.71
(No reviews yet) Write a Review
SKU:
PL-M2000-HYD
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
Controller TypeHydronic Controller
Inputs9 configurable analog inputs
Digital Outputs5 triac, 10-30 VAC source
Analog Outputs3 x 0-10 VDC, 40 mA max
ProtocolModbus RTU (RS485)
Supply24 VAC, Class 2
The Prolon PL-M2000-HYD is a Modbus RTU hydronic controller for water-to-water heat pumps and tank systems, with selectable sequences for hot and cold tanks, dual recovery, open or closed boiler loops, and dual energy boilers.

Specifications sourced from Prolon datasheet PL-DATA-M2000HYD-C/F-EN, REV 7.3.0. Verified September 18, 2026.

Overview

The M2000 HYD controls water-to-water heat pumps and hydronic plants. The sequence is selected in configuration, and the roles of the 9 analog inputs follow the sequence chosen: hot and cold tank, dual recovery system, single hot tank with an open or closed boiler loop, or dual energy boilers. It rotates compressors on lead-lag, resets tank setpoints from outdoor temperature, and accepts network provided demands as setpoint offsets. Built-in auxiliary heat sequences and configurable protection limits are included.

Best For

  • Water-to-water heat pump plants
  • Hot and cold tank systems, including dual recovery arrangements
  • Single hot tank plants with an open or closed boiler loop
  • Dual energy boiler plants needing outdoor reset on tank setpoints

Warranty and Sourcing

ZOT Supply is an authorized Prolon distributor. Every PL-M2000-HYD ships new in factory packaging and is covered by the Prolon manufacturer warranty. For current warranty terms and RMA handling, contact ZOT Supply at 855-825-2811 or sales@zotsupply.com.

Key Features

Selectable hydronic sequences

Hot and cold tank, dual recovery system, single hot tank with open or closed boiler loop, and dual energy boilers.

Compressor lead-lag

Lead-lag sequences rotate the compressors.

Outdoor reset on tanks

Tank setpoints are reset from outdoor temperature.

Heat/cool priority

Heat and cool priority modes are configurable.

Network demand offsets

Setpoints can be offset by network provided demands.

Auxiliary heat

Built-in auxiliary heat sequences are included.

  • Inputs whose roles vary according to the selected sequence
  • Internal clock with configurable schedules and calendars
  • A manual/off/auto switch for each of the eight outputs
  • Stand-alone or networked (up to 127 nodes)
  • 5 digital outputs and 3 analog outputs equipped with resettable fuses
  • Built-in protection sequences with configurable temperature limits and minimum delays

Technical Specifications

SpecificationPL-M2000-HYD
Supply24 VAC +/-10%, 50/60 Hz, Class 2
Power5 VA (consumption), 40 VA (input)
Inputs9 configurable analog inputs whose roles vary according to the selected sequence. Input signals (thermistor / dry contact / 4-20mA / 0-5 VDC) individually configurable for each input
Digital Outputs5 triac outputs, 10-30 VAC source, 300 mA max (resettable fuse)
Analog Outputs3 x 0-10 VDC outputs, 40 mA max (resettable fuse)
Indication Lights (LED)State of each output / Communication / Power / State of microprocessor
MicroprocessorPIC18F6722, 8 bits, 40 MHz, 128 KB FLASH memory
CasingMolded ABS, UL94-HB
CommunicationModbus RTU (RS485), up to 127 nodes
Baud Rates9600, 19200, 38400, 57600, 76800, 115200
ConnectionRemovable screw-type terminal blocks (max 16 AWG) and RJ45 modular jacks
Dimensions5.39 in x 4.41 in x 2.25 in (137 mm x 112 mm x 57 mm)
Weight1.05 lbs (0.48 kg)
Environment-4 to 122 °F (-20 to 50 °C) Non-Condensing
CertificationUL916 Energy Management Equipment, CAN/CSA-C22.2, RoHS, FCC part 15: 2012 class B

Documentation

Frequently Asked Questions

What hydronic sequences does the PL-M2000-HYD support?

Hot and cold tank, dual recovery system, single hot tank with an open or closed boiler loop, and dual energy boilers. The roles of the 9 analog inputs vary according to the sequence selected.

Does the PL-M2000-HYD control water-to-water heat pumps?

Yes. It is designed to control a variety of water-to-water heat pumps and hydronic systems, with lead-lag sequences for the compressors.

Can tank setpoints be reset from outdoor temperature?

Yes. The M2000 HYD applies outdoor temperature reset to the tank setpoints, and setpoints can also be offset by network provided demands.

What input signal types does the PL-M2000-HYD accept?

Each of the 9 analog inputs is individually configurable for thermistor, dry contact, 4-20mA, or 0-5 VDC.

What outputs does the PL-M2000-HYD provide?

5 triac digital outputs rated 10-30 VAC source, 300 mA max with a resettable fuse, plus 3 analog outputs at 0-10 VDC, 40 mA max with a resettable fuse.

Controller Type:
Hydronic
Digital Outputs:
5
Analog Outputs:
3
Inputs:
9
Communication:
Modbus RTU (RS485)
Product Series:
M2000