| Gas Detected | Nitrogen Dioxide (NO2) |
|---|---|
| Measuring Range | 0 to 20 ppm |
| Resolution | 0.1 ppm |
| Sensor Type | Electrochemical cell |
| Sensing Method | Diffusion |
| Sensor Life | Two years |
| Low Alarm | 2.5 ppm |
|---|---|
| High Alarm | 5 ppm |
| Audible | 90 dB at 4 in. (10 cm) |
| Visual | Red flashing LEDs and on-screen indication |
| Tactile | Vibration alarm |
| Alarm Level Set | User selectable via PM Link and PC software |
| Battery | 3.6 V 1.2 Ah lithium, non-replaceable |
|---|---|
| Operating Life | 24 months based on two minutes of alarm per day with limited IR communication use |
| Event Logging | 30 events (alarms and bumps) |
| Sensor Life Notification | Life indication screen in months, days or hours, plus end-of-life warning inside 30 days |
| Dimensions | 3.34 in. (L) x 1.92 in. (W) x 1.56 in. (H) with clip (8.48 x 4.87 x 3.96 cm) |
|---|---|
| Weight | 3.3 oz. (93 g) with battery and clip |
| Housing Material | Polycarbonate and rubber |
| Color | Orange |
| Mounting | Clip |
| Display | LCD display |
| Operating Temperature | -40 to 122 °F (-40 to 50 °C) |
| Operating Humidity | 5 to 95 % RH, non-condensing |
| Ingress Rating | IP67 |
| North America | UL-913 and CSA-C22.2 No. 157. Class I, Division 1 and 2, Groups A, B, C, D. Class I, Zone 0, AEx ia IIC T4 Ga |
|---|---|
| ATEX | II 1 G Ex ia IIC T4 Ga IP67, KRH 17 ATEX 0013, Directive 2014/34/EU |
| IECEx | Ex ia IIC T4 |
| Other | INMETRO; KCS Ex ia IIC T4 |
| EMC | Electromagnetic Compatibility Directive 2014/30/EU |
| Quality System | Manufacturer certified compliant with ISO 9001:2000 provisions |
| Country of Origin | South Korea |
| ECCN | EAR99 |
Documentation
Related Products
Frequently Asked Questions
What does the AimSafety PM100-NO2 detect?
The PM100-NO2 detects Nitrogen Dioxide (NO2) over a range of 0 to 20 ppm with 0.1 ppm resolution, using a diffusion-type electrochemical cell.
What are the factory alarm set points on the PM100-NO2?
The low alarm is 2.5 ppm and the high alarm is 5 ppm. Both are user selectable through the PM Link PC interface and software.
How long does the PM100-NO2 last?
The PM100 operates continuously for two years, based on two minutes of alarm per day with limited IR communication use. The lithium battery and sensor are not replaceable, and the monitor displays a warning during its final 30 days of life.
Can the PM100-NO2 be turned off?
No. Once activated the PM100 is designed to run continuously for the life of the instrument and cannot be switched off. Check the activate-by date on the box before putting a unit into service.
Is the PM100-NO2 intrinsically safe?
Yes. It is certified to UL-913 and CSA-C22.2 No. 157 for Class I, Division 1 and 2, Groups A, B, C and D, and carries ATEX II 1 G Ex ia IIC T4 Ga IP67, IECEx Ex ia IIC T4 and INMETRO approvals.
Can the PM100-NO2 be used with the PM100-STN calibration station?
No. The PM100-STN bump test and calibration station is published as compatible with the CO, H2S and O2 models only. Bump test and calibrate the PM100-NO2 using the PM Link PC interface with a calibration hood, regulator and the matching calibration gas.
- Product Type:
- Portable Gas Monitor
- Gas Detected:
- Nitrogen Dioxide (NO2)
- Number of Gases:
- 1
- Measuring Range:
- 0-20 ppm
- Sensor Type:
- Electrochemical
- Ingress Rating:
- IP67
- Hazardous Location:
- Class I Div 1
- Power Source:
- Non-Replaceable Lithium
- Operating Life:
- 2 Years
- Maintenance:
- Maintenance-Free