The AimSafety PM100-H2S is a maintenance-free disposable single-gas personal monitor that continuously measures hydrogen sulfide (h2s) over 0 to 100 ppm and operates for two years without battery or sensor replacement.
Specifications on this page are taken from the PM100 Series Data Sheet (Macurco, 1/2026), PM100 Personal Single-Gas Monitor User Manual Rev. 3.0 and the AimSafety line card.
Best For
Warranty
Key Features
Technical Specifications
| Gas Detected | Hydrogen Sulfide (H2S) |
|---|---|
| Measuring Range | 0 to 100 ppm |
| Resolution | 0.1 ppm |
| Sensor Type | Electrochemical cell |
| Sensing Method | Diffusion |
| Sensor Life | Two years |
| Low Alarm | 10 ppm |
|---|---|
| High Alarm | 15 ppm |
| Audible | 90 dB at 4 in. (10 cm) |
| Visual | Red flashing LEDs and on-screen indication |
| Tactile | Vibration alarm |
| Alarm Level Set | User selectable via PM Link and PC software |
| Battery | 3.6 V 1.2 Ah lithium, non-replaceable |
|---|---|
| Operating Life | 24 months based on two minutes of alarm per day with limited IR communication use |
| Event Logging | 30 events (alarms and bumps) |
| Sensor Life Notification | Life indication screen in months, days or hours, plus end-of-life warning inside 30 days |
| Dimensions | 3.34 in. (L) x 1.92 in. (W) x 1.56 in. (H) with clip (8.48 x 4.87 x 3.96 cm) |
|---|---|
| Weight | 3.3 oz. (93 g) with battery and clip |
| Housing Material | Polycarbonate and rubber |
| Color | Orange |
| Mounting | Clip |
| Display | LCD display |
| Operating Temperature | -40 to 122 °F (-40 to 50 °C) |
| Operating Humidity | 5 to 95 % RH, non-condensing |
| Ingress Rating | IP67 |
| North America | UL-913 and CSA-C22.2 No. 157. Class I, Division 1 and 2, Groups A, B, C, D. Class I, Zone 0, AEx ia IIC T4 Ga |
|---|---|
| ATEX | II 1 G Ex ia IIC T4 Ga IP67, KRH 17 ATEX 0013, Directive 2014/34/EU |
| IECEx | Ex ia IIC T4 |
| Other | INMETRO; KCS Ex ia IIC T4 |
| EMC | Electromagnetic Compatibility Directive 2014/30/EU |
| Quality System | Manufacturer certified compliant with ISO 9001:2000 provisions |
| Country of Origin | South Korea |
| ECCN | EAR99 |
Documentation
Related Products
Frequently Asked Questions
What does the AimSafety PM100-H2S detect?
The PM100-H2S detects Hydrogen Sulfide (H2S) over a range of 0 to 100 ppm with 0.1 ppm resolution, using a diffusion-type electrochemical cell.
What are the factory alarm set points on the PM100-H2S?
The low alarm is 10 ppm and the high alarm is 15 ppm. Both are user selectable through the PM Link PC interface and software.
How long does the PM100-H2S last?
The PM100 operates continuously for two years, based on two minutes of alarm per day with limited IR communication use. The lithium battery and sensor are not replaceable, and the monitor displays a warning during its final 30 days of life.
Can the PM100-H2S be turned off?
No. Once activated the PM100 is designed to run continuously for the life of the instrument and cannot be switched off. Check the activate-by date on the box before putting a unit into service.
Is the PM100-H2S intrinsically safe?
Yes. It is certified to UL-913 and CSA-C22.2 No. 157 for Class I, Division 1 and 2, Groups A, B, C and D, and carries ATEX II 1 G Ex ia IIC T4 Ga IP67, IECEx Ex ia IIC T4 and INMETRO approvals.
How is the PM100-H2S bump tested and calibrated?
The PM100-STN bump test and calibration station handles up to four monitors at a time and is compatible with the CO, H2S and O2 models. The PM Link PC interface performs zero and span calibration and retrieves event logs.
- Product Type:
- Portable Gas Monitor
- Gas Detected:
- Hydrogen Sulfide (H2S)
- Number of Gases:
- 1
- Measuring Range:
- 0-100 ppm
- Sensor Type:
- Electrochemical
- Ingress Rating:
- IP67
- Hazardous Location:
- Class I Div 1
- Power Source:
- Non-Replaceable Lithium
- Operating Life:
- 2 Years
- Maintenance:
- Maintenance-Free