Quick Facts
Meter Class
Revenue grade, 4-quadrant
Communication
BACnet MS/TP (native)
Voltage Range
120-277 Vac L-N, CAT III
Protection
Disconnect + Class CC fuses
Enclosure
NEMA 1, 18-gauge steel
Warranty
10 years
Functional Devices RIBPM413-BC-KIT Enclosed BACnet Power Meter Kit
The Functional Devices RIBPM413-BC-KIT is a complete, prewired revenue-grade power metering package: the BACnet MS/TP RIBPM413-BC meter, a 3-pole 600 V disconnect switch, a Class CC fuse holder, and 2 A fast-acting fuses, all factory-assembled in an 18-gauge steel NEMA 1 enclosure measuring 8.3 x 7.7 x 3.9 inches (9.2 in wide with the switch). Bulletin B2646 requires fusing on the voltage inputs and a marked disconnect device for every installation — the kit delivers that code-required protection out of the box, leaving only the field wiring, current transformers, and MS/TP trunk to terminate.
Inside, the meter is the same revenue-grade, 4-quadrant RIBPM413-BC: self-powered from Line 1 to Neutral at under 2 VA, compatible with any UL or ETL Listed 333 mV current transformer, and bidirectional for NET metering on single-phase or three-phase services from 120 to 277 Vac line-to-neutral. Current transformers are sold separately — size them from the Functional Devices CT series to match the metered load.
Specifications verified against the Functional Devices RIBPM413-BC-KIT datasheet (rev. 2026.02.19), Bulletin B2818 (393309), Bulletin B2646 (393290), and BACnet PICS v1.00 (April 9, 2020).
Best For
- Sub-metering installs where the contractor wants the disconnect and fusing prewired and inspection-ready
- Tenant billing and cost-allocation points on a BACnet building automation system
- NET metering on circuits with on-site generation (solar, cogeneration)
- Standardized metering packages rolled out across multiple panels or sites
Every Functional Devices RIB product, including the RIBPM413-BC-KIT, is backed by the company's 10-year warranty — confidence and peace of mind in every box.
ZOT Supply is an authorized Functional Devices distributor. Every RIBPM413-BC-KIT ships as genuine, factory-warranted product with full manufacturer support.
Key Features
Complete Prewired Package
Meter, disconnect, fuse holder, and fuses arrive factory-assembled and wired in one enclosure. Land the voltage taps, CTs, and MS/TP trunk, and the metering point is done.
Code-Required Protection Built In
Bulletin B2646 calls for Listed 2 A fast-blow fuses and a Listed 600 V disconnect marked as the disconnect device. The kit includes a 3-pole 600 V, 16 A disconnect switch and Class CC fast-acting fuses already in circuit.
Revenue-Grade RIBPM413-BC Inside
The metering board measures voltage, current, and power to 0.5% accuracy (under 0.2% typical across the working range) and power factor to 0.5% between 0.5 and 1.0, with 4-quadrant energy resolution.
Native BACnet MS/TP
BACnet Protocol Revision 14, B-ASC profile, with baud rates from 9600 to 115200 set over the network. Defaults ship as Device ID 277050, MAC 50, 38400-N-8-1.
Bidirectional NET Metering
Net counters accumulate consumption as positive and generation as negative, while split counters report total import and export energy separately, so utility-style reconciliation is available straight from BACnet.
Rugged NEMA 1 Steel Enclosure
18-gauge steel with a screw-down cover, 8.3 x 7.7 x 3.9 inches (9.2 in wide with switch), UL Listed, CE, and RoHS, suitable for indoor mounting close to the panel or load being metered.
Technical Specifications
| Functional Devices RIBPM413-BC-KIT Specifications | |
|---|---|
| Power Meter (RIBPM413-BC) | |
| Power Input Rating | Powered from Line 1 to Neutral, 120-277 Vac, < 2 VA; neutral connection required |
| Frequency | 50/60 Hz |
| Headers | Pluggable screw terminals, accept 12 to 28 AWG wire |
| Operating Temperature | -20 to 70 °C, -4 to 158 °F |
| Humidity | 5 to 95% RH (noncondensing) |
| Altitude | Up to 2,000 m; indoor use only |
| Board Dimensions | 2.75 in H x 4.5 in W x 0.85 in D with headers installed |
| Terminal Torque | 4.43 in-lbs |
| Approvals | CE, UL Listed, UL 61010-1 and UL 61010-2-30, C-UL, RoHS, FCC Part 15 Class B |
| Disconnect Switch | |
| Rating | 3-pole, 16 A, 600 Vac; 10 kA interrupt |
| Ambient Temperature | -25 to 50 °C, -13 to 122 °F |
| Wire Gauge / Torque | 10-14 AWG; 7 in-lbs |
| Mechanical Life | 1 million cycles |
| Approvals | UL508, IEC 60947-3, EN 60947-3, CSA 22.2, CE, RoHS |
| Fuses and Fuse Holder | |
| Fuses | Class CC, fast-acting, 2 A, 600 Vac; 200 kA interrupt; CSA Certified, CE, RoHS |
| Fuse Holder | Class CC, 3-pole, 30 A, 600 Vac; 200 kA interrupt; max ambient 125 °C; 10-14 AWG, 20 in-lbs; UL Listed, CE, CSA Certified, RoHS |
| Enclosure | |
| Construction | 18-gauge steel, screw-down cover |
| Dimensions | 8.3 in H x 7.7 in W x 3.9 in D (9.2 in W with switch) |
| Rating | NEMA 1; UL Listed, CE, RoHS |
| Metered Circuit | |
| Voltage Range | 120-277 Vac L-N (CAT III); 1-phase 2/3-wire, 3-phase 4-wire |
| Voltage Overload | 1.1 x voltage range |
| Voltage Burden | < 0.1 VA at 277 Vac |
| Frequency Range | 45-65 Hz |
| Current Overload | 1.2 x CT output |
| Power Overload | 1.2 x voltage range x CT output |
| Current Transformer Input | 333 mV output CTs (UL or ETL Listed); sold separately |
| Measurement Accuracy | |
| Voltage | 0.5%, < 0.2% typical from 80-120% |
| Current | 0.5%, < 0.2% typical from 10-120% |
| Power | 0.5%, < 0.2% typical from 10-120% |
| Power Factor | 0.5% between 0.5 and 1.0 |
| BACnet | |
| Protocol | BACnet MS/TP, Protocol Revision 14, B-ASC profile |
| Defaults | Device ID 277050; MAC address 50; 38400 baud, N-8-1 |
| Baud Rates | 9600, 19200, 38400, 57600, 76800, 115200; set via BACnet |
| Network Media | 18-22 AWG, 2-core, shielded twisted pair; polarity sensitive |
| Network Termination | 120 ohm resistor at end-of-line device (see Bulletin B2646) |
| Commissioning Note | CT-Ratings object (AV-8005) must be set to the rating of the installed CTs |
| Compliance | |
| Net Metering | Bidirectional; net and split import/export energy registers |
Documentation
Specifications cutsheet, rev. 2026.02.19
Kit contents, connection guide, and safety guidelines (393309)
Meter installation, wiring, LED definitions, and BACnet object map (393290)
PICS v1.00 for the RIBPM413-BC metering board, Protocol Revision 14
C2775E — compatible CT-, CTS-, ROPE-, and MOD-series selection
Related Products
The metering board inside this kit, available separately as an open track-mount device — and the replacement part number per Bulletin B2818.
The same metering board factory-mounted in a compact NEMA 1 housing with a 0.75 in NPT hub, without the disconnect and fusing package.
Compatible Split-Core CTs (333 mV)
All eight split-core models terminate directly on the RIBPM413-BC-KIT CT inputs; size to the metered load and set CT-Ratings (AV-8005) to match.
Rogowski Coils for Large Services (4,000-10,000 A)
For mains and switchgear beyond split-core ratings, wrap a ROPE-series coil around the conductor — then add the matching MOD integrator below.
MOD-Series Integrators for ROPE Coils
A MOD integrator converts the ROPE coil's 70 mV output to the 333 mV standard this meter accepts; choose by phase count (12 or 24 Vdc powered).
Frequently Asked Questions
What is included in the RIBPM413-BC-KIT?
The RIBPM413-BC power meter board, a 3-pole 600 V 16 A disconnect switch, a 3-pole Class CC fuse holder, and 2 A fast-acting Class CC fuses, prewired in an 18-gauge steel NEMA 1 enclosure. Current transformers are not included and are sold separately.
Do I still need to add fuses or a disconnect in the field?
No. Bulletin B2646 requires Listed 2 A fast-blow fuses on the voltage inputs and a Listed 600 V disconnect marked as the disconnect device, and the kit ships with both already wired in circuit.
Which current transformers work with this meter?
Any UL or ETL Listed 333 mV output current transformer. Functional Devices' CT series (25 A through 600 A split-core, solid-core models, and ROPE Rogowski coils with a MOD converter) are drop-in choices. After installation, write the CT rating to the CT-Ratings object (AV-8005) so readings scale correctly.
Does the kit need an external power supply?
No. The RIBPM413-BC meter inside powers itself from the metered circuit, drawing under 2 VA from Line 1 to Neutral. A neutral connection is required, supporting 1-phase 2-wire, 1-phase 3-wire, and 3-phase 4-wire services from 120 to 277 Vac line-to-neutral.
Can it measure energy flowing in both directions?
Yes. The meter is bidirectional for NET metering. Net energy registers accumulate consumption as positive and generation as negative, and split registers (for example EnergyP_Tot_Imp and EnergyP_Tot_Exp) report import and export totals separately.
How does it connect to my building automation system?
Over BACnet MS/TP using 18-22 AWG shielded twisted pair. Defaults are Device ID 277050, MAC address 50, and 38400-N-8-1; all parameters are changed over BACnet. If the meter is the end-of-line device on the trunk, terminate B(+) to A(-) with a 120 ohm resistor.
Is there a replacement part for the meter board?
Yes. Per Bulletin B2818, the meter board in the kit is the standard RIBPM413-BC — order it separately if a replacement is ever needed.
- Supported Protocols:
- BACnet MS/TP
- Meter Type:
- Single Circuit
- Mounting:
- Wall Mount
- Current Channels:
- 3
- Phase Configuration:
- Single or Three Phase
- Voltage Range:
- 120-277 Vac L-N
- CT Input:
- 333 mV
- Accuracy:
- 0.5 Percent Revenue Grade
- Net Metering:
- Bidirectional
- Enclosure:
- NEMA 1 Steel Kit