null Skip to main content

Pilla BSD120CLM : "Emergency Boiler Shut Down" Push Button Station, Maintained (Pull to Reset) 40mm Mushroom Button, One Clear Hinged Lockout Lid, Surface Mount Nema 4/4X Enclosure, Fits 1-3 Contact Blocks

Pilla

$340.00 - $379.00
(No reviews yet) Write a Review
SKU:
BSD120CLM
Condition:
New
Availability:
In Stock - Ships Today
Adding to cart… The item has been added
Part Number
BSD120CLM
Operator
Maintained
Reset
Pull to Reset
Contact Blocks
Fits 1-3
Enclosure
NEMA 4/4X/12
Listing
UL Listed • C-UL

The Pilla BSD120CLM is an emergency boiler shut-down station with a maintained mushroom operator with an integral clear hinged lockout lid that padlocks or seals, mounted in a yellow NEMA 4/4X/12 enclosure with bold luminous "EMERGENCY BOILER SHUT-DOWN" legends. Contact blocks are ordered separately — the standard enclosure accepts 1-3 contact blocks. UL Listed and C-UL Listed.

Best for: Applications requiring lockout/tagout compliance, accidental actuation protection, or a sealable emergency shut-down station.

When to Specify the BSD120CLM — Clear Hinged Lockout Lid

The BSD120CLM adds a clear hinged cover over the mushroom operator that can be padlocked or sealed. The clear lid allows visual inspection of the operator state without opening the cover. Specify when accidental actuation protection is required, when lockout/tagout procedures apply to the boiler shut-down station, or when code requires the station to be sealable for inspection purposes.

SpecificationValue
Part NumberBSD120CLM
FunctionEmergency Boiler Shut-Down Station
Operator TypeMaintained — 40mm Red Mushroom
Operator Inscription"PULL TO RESET" — engraved white lettering
Station Legend"EMERGENCY BOILER SHUT-DOWN" / "PUSH BUTTON" — bold luminous
Reset MethodPull to Reset
Cover / LidClear Hinged Lockout Lid
Contact Block CapacityFits 1-3 contact blocks (PILNCCB or PILNOCB, ordered separately)
Ampere Rating10A
EnclosureNEMA 4, 4X, 12 Yellow Enclosure
MountingSurface mount, external mounting feet top & bottom
AC Utilization CategoryAC-15 — 1.2A @ 600VAC or 3A @ 240VAC or 6A @ 120VAC
Continuous Thermal Current10A
DC Utilization CategoryDC-13 — 0.1A @ 600VDC • 0.5A @ 24VDC
Standard ConformanceEC/EN 60947-5-1
ApprovalsUL Listed (9F36), C-UL (Canada)

Commercial Boiler Rooms

Emergency shut-down for commercial heating boilers in hotels, schools, hospitals, and office buildings

Industrial Heating Plants

Emergency stop for industrial process boilers and steam generation equipment requiring maintained contact

Fuel Shut-Off Interlock

Interfaces to gas valve or fuel oil shut-off controls to de-energize burner on emergency actuation

Mechanical Room Safety

Clearly identified emergency stop point per local fire and mechanical codes

Multi-Circuit Shut-Down

Multiple contact blocks allow simultaneous shut-down of burner, fuel valve, and ventilation circuits

Code-Compliant Emergency Stop

Satisfies NFPA 85, local mechanical codes, and AHJ requirements for identified boiler shut-down stations

Contact Block Selection — PILNCCB vs. PILNOCB

Contact blocks are ordered separately. The PILNCCB (normally closed) opens the circuit when the button is pushed — the standard configuration for boiler shut-down where pushing breaks the control circuit. The PILNOCB (normally open) closes the circuit when pushed. Order the contact type that matches your control circuit design. Contact blocks accept up to 10 AWG wiring.

UL Listed C-UL (Canada) EC/EN 60947-5-1 NEMA 4 NEMA 4X NEMA 12 AC-15 DC-13
What contact blocks does the BSD120CLM accept?
The BSD120CLM accepts Pilla PILNCCB (normally closed) and PILNOCB (normally open) contact blocks, ordered separately. The standard enclosure fits 1-3 contact blocks. Normally closed (PILNCCB) is the standard choice for boiler shut-down circuits where pushing the button opens the control circuit.
How is the BSD120CLM reset after actuation?
The BSD120CLM resets by pull to reset. The maintained mushroom operator stays in the latched position after being pushed and must be deliberately reset before the boiler control circuit can be re-energized.
What is the enclosure rating on the BSD120CLM?
The BSD120CLM carries a NEMA 4/4X/12 enclosure rating. NEMA 4 and 4X provide protection against rain, splashing water, hose-directed water, and corrosion. NEMA 12 provides protection against dust and dripping non-corrosive liquids.
Does the BSD120 series include contact blocks?
No. All BSD120 series stations ship as the housing and operator assembly. Contact blocks are ordered separately. Use PILNCCB for normally closed contacts and PILNOCB for normally open contacts.
Why specify the BSD120CLM over the standard BSD120?
Clear hinged lockout lid, padlockable See all BSD120 series options on this page to find the configuration that best matches your application requirements.

Other BSD120 options: BSD120 | BSD120IL | BSD120RP1 | BSD120GM | BSD120MO | BSD120GMY | BSD120KR | BSD120TW | BSD120SD | BSD120XD | BSD120MDY | BSD120N1KRCLMvr

Button Style:
Mushroom Button
Button Type:
Maintained
Label Legend:
Boiler Shut Down
Nema Rating:
Nema 4X and 12
Lockout Lid: