null Skip to main content

Pilla BSD120SD : Emergency Boiler Shut Down Push Button Operator Station, Maintained "Pull to Reset" 40mm Red Mushroom Operator, Surface Mount Nema 4x & 12 Nonmetallic Enclosure, 12 Amp at 120 VAC, 10 Amp at 24 VDC, Super Depth Fits 15 Contact Blocks

Pilla

$358.00 - $397.00
(No reviews yet) Write a Review
SKU:
BSD120SD
Condition:
New
Availability:
In Stock - Ships Today
Adding to cart… The item has been added
Part Number
BSD120SD
Operator
Maintained
Reset
Pull to Reset
Contact Blocks
Fits 15
Enclosure
NEMA 4X/12
Listing
UL Listed • C-UL

The Pilla BSD120SD is an emergency boiler shut-down station with a maintained mushroom operator in a super depth enclosure that fits up to 15 contact blocks, mounted in a yellow NEMA 4X/12 enclosure with bold luminous "EMERGENCY BOILER SHUT-DOWN" legends. Contact blocks are ordered separately — the standard enclosure accepts 15 contact blocks. UL Listed and C-UL Listed.

Best for: Complex industrial boiler installations requiring simultaneous shut-down of up to 15 independent control circuits from one station.

When to Specify the BSD120SD — Super Depth for Complex Control Circuits

The BSD120SD uses a deeper enclosure than the standard BSD120, providing capacity for up to 15 contact blocks. Specify when the boiler shut-down station must simultaneously switch a large number of control circuits — such as complex industrial installations requiring independent shut-down of multiple burners, fuel trains, fans, pumps, and interlocks from a single station. The 12A @ 120VAC / 10A @ 24VDC rating provides increased capacity over the standard model.

SpecificationValue
Part NumberBSD120SD
FunctionEmergency Boiler Shut-Down Station
Operator TypeMaintained — 40mm Red Mushroom
Operator Inscription"PULL TO RESET" — engraved white lettering
Station Legend"EMERGENCY BOILER SHUT-DOWN" / "PUSH BUTTON" — bold luminous
Reset MethodPull to Reset
Contact Block CapacityFits 15 contact blocks (PILNCCB or PILNOCB, ordered separately)
Ampere Rating12A @ 120VAC / 10A @ 24VDC
EnclosureNEMA 4X, 12 Non-Metallic Enclosure
MountingSurface mount, external mounting feet top & bottom
AC Utilization CategoryAC-15 — 1.2A @ 600VAC or 3A @ 240VAC or 6A @ 120VAC
Continuous Thermal Current10A
DC Utilization CategoryDC-13 — 0.1A @ 600VDC • 0.5A @ 24VDC
Standard ConformanceEC/EN 60947-5-1
ApprovalsUL Listed (9F36), C-UL (Canada)

Commercial Boiler Rooms

Emergency shut-down for commercial heating boilers in hotels, schools, hospitals, and office buildings

Industrial Heating Plants

Emergency stop for industrial process boilers and steam generation equipment requiring maintained contact

Fuel Shut-Off Interlock

Interfaces to gas valve or fuel oil shut-off controls to de-energize burner on emergency actuation

Mechanical Room Safety

Clearly identified emergency stop point per local fire and mechanical codes

Multi-Circuit Shut-Down

Multiple contact blocks allow simultaneous shut-down of burner, fuel valve, and ventilation circuits

Code-Compliant Emergency Stop

Satisfies NFPA 85, local mechanical codes, and AHJ requirements for identified boiler shut-down stations

Contact Block Selection — PILNCCB vs. PILNOCB

Contact blocks are ordered separately. The PILNCCB (normally closed) opens the circuit when the button is pushed — the standard configuration for boiler shut-down where pushing breaks the control circuit. The PILNOCB (normally open) closes the circuit when pushed. Order the contact type that matches your control circuit design. Contact blocks accept up to 10 AWG wiring.

UL Listed C-UL (Canada) EC/EN 60947-5-1 NEMA 4 NEMA 4X NEMA 12 AC-15 DC-13
What contact blocks does the BSD120SD accept?
The BSD120SD accepts Pilla PILNCCB (normally closed) and PILNOCB (normally open) contact blocks, ordered separately. The standard enclosure fits 15 contact blocks. Normally closed (PILNCCB) is the standard choice for boiler shut-down circuits where pushing the button opens the control circuit.
How is the BSD120SD reset after actuation?
The BSD120SD resets by pull to reset. The maintained mushroom operator stays in the latched position after being pushed and must be deliberately reset before the boiler control circuit can be re-energized.
What is the enclosure rating on the BSD120SD?
The BSD120SD carries a NEMA 4X/12 enclosure rating. NEMA 4 and 4X provide protection against rain, splashing water, hose-directed water, and corrosion. NEMA 12 provides protection against dust and dripping non-corrosive liquids.
Does the BSD120 series include contact blocks?
No. All BSD120 series stations ship as the housing and operator assembly. Contact blocks are ordered separately. Use PILNCCB for normally closed contacts and PILNOCB for normally open contacts.
Why specify the BSD120SD over the standard BSD120?
Super depth enclosure, fits up to 15 contact blocks See all BSD120 series options on this page to find the configuration that best matches your application requirements.

Other BSD120 options: BSD120 | BSD120IL | BSD120CLM | BSD120RP1 | BSD120GM | BSD120MO | BSD120GMY | BSD120KR | BSD120TW | BSD120XD | BSD120MDY | BSD120N1KRCLMvr

Button Style:
Mushroom Button
Button Type:
Maintained
Label Legend:
Boiler Shut Down
Nema Rating:
Nema 4X and 12
Lockout Lid:
No