Pilla BSD120MDY : Emergency Boiler Shut Down Push Button Operator Station, Maintained "Pull to Reset" 40mm Red Mushroom Operator, Surface Mount Nema 4x & 12 Nonmetallic Enclosure, Maximum Duty Model 20 Amps

Pilla

MSRP: $432.00
$302.00
(You save $130.00 )
(No reviews yet) Write a Review
SKU:
BSD120MDY
Condition:
New
Availability:
In Stock - Ships Today
Adding to cart… The item has been added
Part Number
BSD120MDY
 
Operator
Maintained Push-Pull
 
Reset
Pull to Reset
 
Contact Blocks
Fits 1-3
 
Enclosure
NEMA 4X/12
 
Listing
UL Listed • C-UL

The Pilla BSD120MDY is an emergency boiler shut-down station with a maintained push-pull mushroom operator rated for 20 amp maximum duty operation, mounted in a yellow NEMA 4X/12 enclosure with bold luminous "EMERGENCY BOILER SHUT-DOWN" legends. Contact blocks are ordered separately — the standard enclosure accepts 1-3 contact blocks. UL Listed and C-UL Listed.

Best for: High-current boiler shut-down applications requiring a 20A rated station for direct switching of larger loads.

When to Specify the BSD120MDY — Maximum Duty 20A Rating

The BSD120MDY is the maximum duty version of the BSD120, rated at 20 amps compared to the standard 10A model. Specify when the boiler shut-down station must directly switch higher-current loads — such as larger motor loads, high-current fuel valve coils, or industrial heating equipment with elevated current requirements that exceed the 10A rating of the standard BSD120.

Specification Value
Part Number BSD120MDY
Function Emergency Boiler Shut-Down Station
Operator Type Maintained Push-Pull — 40mm Red Mushroom
Operator Inscription "PULL TO RESET" — engraved white lettering
Station Legend "EMERGENCY BOILER SHUT-DOWN" / "PUSH BUTTON" — bold luminous
Reset Method Pull to Reset
Contact Block Capacity Fits 1-3 contact blocks (PILNCCB or PILNOCB, ordered separately)
Ampere Rating 20A
Enclosure NEMA 4X, 12 Non-Metallic Enclosure
Mounting Surface mount, external mounting feet top & bottom
AC Utilization Category AC-15 — 1.2A @ 600VAC or 3A @ 240VAC or 6A @ 120VAC
Continuous Thermal Current 10A
DC Utilization Category DC-13 — 0.1A @ 600VDC • 0.5A @ 24VDC
Standard Conformance EC/EN 60947-5-1
Approvals UL Listed (9F36), C-UL (Canada)
Standard

BSD120

Maintained pull-to-reset, standard depth, 1-3 contact blocks

Illuminated LED

BSD120IL

Illuminated red LED operator, 24-120VAC/DC, 1-3 contact blocks

Clear Hinged Lid

BSD120CLM

Pull-to-reset with clear hinged lockout/padlockable lid

Raise-Lid Momentary

BSD120RP1

Padlockable solid lid, raise lid to access momentary button

Red Metal Guard

BSD120GM

Pull-to-reset with lockable red metal guard

Momentary

BSD120MO

Self-resetting momentary operator, no latching

Yellow Plastic Guard

BSD120GMY

Pull-to-reset with lockable yellow non-metallic guard

Key Release

BSD120KR

Key required to reset after actuation, 2 keys included

Turn to Reset

BSD120TW

Maintained turn-to-reset operator

Super Depth

BSD120SD

Super depth, fits up to 15 contact blocks

Extra Depth

BSD120XD

Extra depth, fits up to 9 contact blocks

This Product

BSD120MDY

Maximum duty 20 amp rating

NEMA 1 Keyed + Cover

BSD120N1KRCLMvr

NEMA 1 metallic, keyed maintained, clear lift cover, voltage indicator

 

Commercial Boiler Rooms

Emergency shut-down for commercial heating boilers in hotels, schools, hospitals, and office buildings

 

Industrial Heating Plants

Emergency stop for industrial process boilers and steam generation equipment requiring maintained contact

 

Fuel Shut-Off Interlock

Interfaces to gas valve or fuel oil shut-off controls to de-energize burner on emergency actuation

 

Mechanical Room Safety

Clearly identified emergency stop point per local fire and mechanical codes

 

Multi-Circuit Shut-Down

Multiple contact blocks allow simultaneous shut-down of burner, fuel valve, and ventilation circuits

 

Code-Compliant Emergency Stop

Satisfies NFPA 85, local mechanical codes, and AHJ requirements for identified boiler shut-down stations

Contact Block Selection — PILNCCB vs. PILNOCB

Contact blocks are ordered separately. The PILNCCB (normally closed) opens the circuit when the button is pushed — the standard configuration for boiler shut-down where pushing breaks the control circuit. The PILNOCB (normally open) closes the circuit when pushed. Order the contact type that matches your control circuit design. Contact blocks accept up to 10 AWG wiring.

UL Listed C-UL (Canada) EC/EN 60947-5-1 NEMA 4 NEMA 4X NEMA 12 AC-15 DC-13
What contact blocks does the BSD120MDY accept?
The BSD120MDY accepts Pilla PILNCCB (normally closed) and PILNOCB (normally open) contact blocks, ordered separately. The standard enclosure fits 1-3 contact blocks. Normally closed (PILNCCB) is the standard choice for boiler shut-down circuits where pushing the button opens the control circuit.
How is the BSD120MDY reset after actuation?
The BSD120MDY resets by pull to reset. The maintained mushroom operator stays in the latched position after being pushed and must be deliberately reset before the boiler control circuit can be re-energized.
What is the enclosure rating on the BSD120MDY?
The BSD120MDY carries a NEMA 4X/12 enclosure rating. NEMA 4 and 4X provide protection against rain, splashing water, hose-directed water, and corrosion. NEMA 12 provides protection against dust and dripping non-corrosive liquids.
Does the BSD120 series include contact blocks?
No. All BSD120 series stations ship as the housing and operator assembly. Contact blocks are ordered separately. Use PILNCCB for normally closed contacts and PILNOCB for normally open contacts.
Why specify the BSD120MDY over the standard BSD120?
Maximum duty model, 20 amp rating See all BSD120 series options on this page to find the configuration that best matches your application requirements.

Other BSD120 options: BSD120 | BSD120IL | BSD120CLM | BSD120RP1 | BSD120GM | BSD120MO | BSD120GMY | BSD120KR | BSD120TW | BSD120SD | BSD120XD | BSD120N1KRCLMvr

Button Style:
Mushroom Button
Button Type:
Maintained
Label Legend:
Boiler Shut Down
Nema Rating:
Nema 4X and 12
Lockout Lid:
No