null Skip to main content
Image coming soon

Pilla BSD120N1KRCLMvr : Emergency Boiler Shut Down Operator Station, Keyed Maintained 40mm Red Mushroom Operator, Surface Mount Nema 1 Metallic Enclosure, Clear Lift Cover, Voltage Indicator, 12 Amp at 120 VAC, 10 Amp at 24 VDC

Pilla

MSRP: $819.00
$573.00
(You save $246.00 )
(No reviews yet) Write a Review
SKU:
BSD120N1KRCLMvr
Condition:
New
Availability:
Ships in 1 Week
Adding to cart… The item has been added
Part Number
BSD120N1KRCLMvr
Operator
Keyed Maintained
Reset
Key Required to Reset
Contact Blocks
Fits 1-3
Enclosure
NEMA 1
Listing
UL Listed • C-UL

The Pilla BSD120N1KRCLMvr is an emergency boiler shut-down station with a keyed maintained operator with a clear lift cover and voltage indicator in a NEMA 1 metallic enclosure, mounted in a yellow NEMA 1 enclosure with bold luminous "EMERGENCY BOILER SHUT-DOWN" legends. Contact blocks are ordered separately — the standard enclosure accepts 1-3 contact blocks. UL Listed and C-UL Listed.

Best for: Indoor boiler rooms requiring keyed access control, accidental actuation protection, and circuit status indication in a single station.

When to Specify the BSD120N1KRCLMvr — NEMA 1 Keyed with Cover and Voltage Indicator

The BSD120N1KRCLMvr combines a keyed maintained operator, clear lift cover, and built-in voltage indicator in a NEMA 1 metallic enclosure. The voltage indicator provides live circuit confirmation at the station. The clear lift cover protects against accidental actuation while permitting visual inspection. The keyed reset requires authorized personnel to reset after shut-down. Specify for indoor boiler rooms where NEMA 1 rating is sufficient and maximum access control, accidental actuation protection, and circuit status visibility are all required at a single station.

SpecificationValue
Part NumberBSD120N1KRCLMvr
FunctionEmergency Boiler Shut-Down Station
Operator TypeKeyed Maintained — 40mm Red Mushroom
Operator Inscription"PULL TO RESET" / "TURN TO RESET" — engraved white lettering
Station Legend"EMERGENCY BOILER SHUT-DOWN" / "PUSH BUTTON" — bold luminous
Reset MethodKey Required to Reset
Cover / LidClear Lift Cover
Key ResetYes — key required to reset after actuation, 2 keys included
Contact Block CapacityFits 1-3 contact blocks (PILNCCB or PILNOCB, ordered separately)
Ampere Rating12A @ 120VAC / 10A @ 24VDC
EnclosureNEMA 1 Metallic Enclosure
MountingSurface mount, external mounting feet top & bottom
AC Utilization CategoryAC-15 — 1.2A @ 600VAC or 3A @ 240VAC or 6A @ 120VAC
Continuous Thermal Current10A
DC Utilization CategoryDC-13 — 0.1A @ 600VDC • 0.5A @ 24VDC
Standard ConformanceEC/EN 60947-5-1
ApprovalsUL Listed (9F36), C-UL (Canada)

Commercial Boiler Rooms

Emergency shut-down for commercial heating boilers in hotels, schools, hospitals, and office buildings

Industrial Heating Plants

Emergency stop for industrial process boilers and steam generation equipment requiring maintained contact

Fuel Shut-Off Interlock

Interfaces to gas valve or fuel oil shut-off controls to de-energize burner on emergency actuation

Mechanical Room Safety

Clearly identified emergency stop point per local fire and mechanical codes

Multi-Circuit Shut-Down

Multiple contact blocks allow simultaneous shut-down of burner, fuel valve, and ventilation circuits

Code-Compliant Emergency Stop

Satisfies NFPA 85, local mechanical codes, and AHJ requirements for identified boiler shut-down stations

Contact Block Selection — PILNCCB vs. PILNOCB

Contact blocks are ordered separately. The PILNCCB (normally closed) opens the circuit when the button is pushed — the standard configuration for boiler shut-down where pushing breaks the control circuit. The PILNOCB (normally open) closes the circuit when pushed. Order the contact type that matches your control circuit design. Contact blocks accept up to 10 AWG wiring.

UL Listed C-UL (Canada) EC/EN 60947-5-1 NEMA 4 NEMA 4X NEMA 12 AC-15 DC-13
What contact blocks does the BSD120N1KRCLMvr accept?
The BSD120N1KRCLMvr accepts Pilla PILNCCB (normally closed) and PILNOCB (normally open) contact blocks, ordered separately. The standard enclosure fits 1-3 contact blocks. Normally closed (PILNCCB) is the standard choice for boiler shut-down circuits where pushing the button opens the control circuit.
How is the BSD120N1KRCLMvr reset after actuation?
The BSD120N1KRCLMvr resets by key required to reset. A key is required to reset the operator after actuation. This prevents unauthorized restart of the boiler.
What is the enclosure rating on the BSD120N1KRCLMvr?
The BSD120N1KRCLMvr carries a NEMA 1 enclosure rating. NEMA 1 provides protection against dust and light dirt in indoor environments.
Does the BSD120 series include contact blocks?
No. All BSD120 series stations ship as the housing and operator assembly. Contact blocks are ordered separately. Use PILNCCB for normally closed contacts and PILNOCB for normally open contacts.
Why specify the BSD120N1KRCLMvr over the standard BSD120?
NEMA 1 metallic enclosure, clear lift cover, voltage indicator See all BSD120 series options on this page to find the configuration that best matches your application requirements.

Other BSD120 options: BSD120 | BSD120IL | BSD120CLM | BSD120RP1 | BSD120GM | BSD120MO | BSD120GMY | BSD120KR | BSD120TW | BSD120SD | BSD120XD | BSD120MDY

Button Style:
Key Release Button
Button Type:
Maintained
Label Legend:
Boiler Shut Down
Nema Rating:
Nema 1
Lockout Lid:
Yes