Pilla BSD120MO : "Emergency Boiler Shut Down" Push Button Station, Momentary 40mm Mushroom Button, Surface Mount Nema 4/4X Enclosure, Fits 1-3 Contact Blocks

Pilla

MSRP: $294.00
$206.00
(You save $88.00 )
(No reviews yet) Write a Review
SKU:
BSD120MO
Condition:
New
Availability:
Ships in 2-4 Days
Adding to cart… The item has been added
Part Number
BSD120MO
Operator
Momentary
Reset
Self-resetting
Contact Blocks
Fits 1-3
Enclosure
NEMA 4/4X/12
Listing
UL Listed • C-UL

The Pilla BSD120MO is an emergency boiler shut-down station with a momentary 40mm red mushroom operator that self-resets on release — does not latch, mounted in a yellow NEMA 4/4X/12 enclosure with bold luminous "EMERGENCY BOILER SHUT-DOWN" legends. Contact blocks are ordered separately — the standard enclosure accepts 1-3 contact blocks. UL Listed and C-UL Listed.

Best for: Applications where the boiler control circuit latches off internally and requires only a momentary shut-down signal.

Maintained vs. Momentary — When to Specify BSD120MO

The BSD120MO uses a momentary operator that self-resets when released, unlike the standard BSD120 which maintains its actuated position until deliberately reset. A momentary contact is the correct choice when the boiler control circuit is designed to latch off internally after a brief shut-down signal, or when the application requires the station to be self-resetting for repeated use without manual reset. If your boiler control circuit requires the shut-down signal to persist until manually cleared, specify the maintained BSD120 instead.

SpecificationValue
Part NumberBSD120MO
FunctionEmergency Boiler Shut-Down Station
Operator TypeMomentary — 40mm Red Mushroom
Operator Inscription"PUSH BUTTON" — engraved white lettering
Station Legend"EMERGENCY BOILER SHUT-DOWN" / "PUSH BUTTON" — bold luminous
Reset MethodSelf-resetting
Contact Block CapacityFits 1-3 contact blocks (PILNCCB or PILNOCB, ordered separately)
Ampere Rating10A
EnclosureNEMA 4, 4X, 12 Yellow Enclosure
MountingSurface mount, external mounting feet top & bottom
AC Utilization CategoryAC-15 — 1.2A @ 600VAC or 3A @ 240VAC or 6A @ 120VAC
Continuous Thermal Current10A
DC Utilization CategoryDC-13 — 0.1A @ 600VDC • 0.5A @ 24VDC
Standard ConformanceEC/EN 60947-5-1
ApprovalsUL Listed (9F36), C-UL (Canada)

Commercial Boiler Rooms

Emergency shut-down for commercial heating boilers in hotels, schools, hospitals, and office buildings

Industrial Heating Plants

Emergency stop for industrial process boilers and steam generation equipment requiring maintained contact

Fuel Shut-Off Interlock

Interfaces to gas valve or fuel oil shut-off controls to de-energize burner on emergency actuation

Mechanical Room Safety

Clearly identified emergency stop point per local fire and mechanical codes

Multi-Circuit Shut-Down

Multiple contact blocks allow simultaneous shut-down of burner, fuel valve, and ventilation circuits

Code-Compliant Emergency Stop

Satisfies NFPA 85, local mechanical codes, and AHJ requirements for identified boiler shut-down stations

Contact Block Selection — PILNCCB vs. PILNOCB

Contact blocks are ordered separately. The PILNCCB (normally closed) opens the circuit when the button is pushed — the standard configuration for boiler shut-down where pushing breaks the control circuit. The PILNOCB (normally open) closes the circuit when pushed. Order the contact type that matches your control circuit design. Contact blocks accept up to 10 AWG wiring.

UL Listed C-UL (Canada) EC/EN 60947-5-1 NEMA 4 NEMA 4X NEMA 12 AC-15 DC-13
What contact blocks does the BSD120MO accept?
The BSD120MO accepts Pilla PILNCCB (normally closed) and PILNOCB (normally open) contact blocks, ordered separately. The standard enclosure fits 1-3 contact blocks. Normally closed (PILNCCB) is the standard choice for boiler shut-down circuits where pushing the button opens the control circuit.
How is the BSD120MO reset after actuation?
The BSD120MO resets by self-resetting. The momentary operator self-resets on release without requiring a separate reset action.
What is the enclosure rating on the BSD120MO?
The BSD120MO carries a NEMA 4/4X/12 enclosure rating. NEMA 4 and 4X provide protection against rain, splashing water, hose-directed water, and corrosion. NEMA 12 provides protection against dust and dripping non-corrosive liquids.
Does the BSD120 series include contact blocks?
No. All BSD120 series stations ship as the housing and operator assembly. Contact blocks are ordered separately. Use PILNCCB for normally closed contacts and PILNOCB for normally open contacts.
Why specify the BSD120MO over the standard BSD120?
Momentary mushroom operator, self-resetting on release See all BSD120 series options on this page to find the configuration that best matches your application requirements.

Other BSD120 options: BSD120 | BSD120IL | BSD120CLM | BSD120RP1 | BSD120GM | BSD120GMY | BSD120KR | BSD120TW | BSD120SD | BSD120XD | BSD120MDY | BSD120N1KRCLMvr

Button Style:
Mushroom Button
Button Type:
Momentary
Label Legend:
Boiler Shut Down
Nema Rating:
Nema 4X and 12
Lockout Lid:
No